{"product_id":"ge-fanuc-a03b-0807-c114-digital-input","title":"GE Fanuc A03B-0807-C114 Digital Input","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc A03B-0807-C114\u003c\/strong\u003e serves as the primary \u003cstrong\u003eAID16L\u003c\/strong\u003e Digital Input Module utilized to execute 24 VDC discrete signal acquisition across CNC and machine control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA03B-0807-C114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 lbs (0.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O Slot Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic-side backplane current draw nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Module Type\u003c\/td\u003e\n\u003ctd\u003eAID16L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Part\u003c\/td\u003e\n\u003ctd\u003eA03B-0819-C114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Communication and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe input interface routes digital field state transitions via high-speed backplane bus communication velocity to ensure real-time scanning by the main CPU. Integrated optocoupler isolation circuits decouple incoming 24 VDC sensor signals from internal logic lines, neutralizing common-mode ground potential loops and transient line spikes. The 16-point I\/O density scaling allows efficient wiring layout for proximity switches, pushbuttons, and limit sensors while maintaining strict signal noise rejection over field control networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the official direct replacement for the discontinued A03B-0807-C114 module?\u003c\/p\u003e\n\u003cp\u003eA: The designated manufacturer replacement for this module is model A03B-0819-C114, which offers equivalent physical, pinout, and signal specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for the AID16L module on a live rack?\u003c\/p\u003e\n\u003cp\u003eA: No, system power to the rack backplane must be completely de-energized prior to inserting or removing the module to prevent electrical stress to the logic bus.\u003c\/p\u003e\n\u003cp\u003eQ: What field voltage range is required to drive the input points on this module?\u003c\/p\u003e\n\u003cp\u003eA: The digital input channels are rated for standard nominal 24 VDC field signal levels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTurn off all system rack power supplies and verify that external field-side 24 VDC loop power is isolated before starting installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit card edge with the targeted backplane rack slot and push firmly until the retention mechanism clicks securely.\u003c\/li\u003e\n\u003cli\u003eWire digital input field lines to the terminal block using stranded copper conductors with appropriate ferrules and strain relief.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC discrete signal cabling in separate wireways away from high-voltage AC lines and high-frequency drive output leads to mitigate EMI noise.\u003c\/li\u003e\n\u003cli\u003eBond all cable shield wires and rack ground terminals directly to a common protective earth (PE) ground bus bar using short, low-impedance straps.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":66735474540659,"sku":"A03B-0807-C114","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A03B-0807-C171_Cocoai_1f26f067-7699-4098-97af-ca3cc216f8c3.jpg?v=1790668521","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-a03b-0807-c114-digital-input","provider":"DcsSupplier Limited","version":"1.0","type":"link"}