{"product_id":"ge-fanuc-a08b-0031-b001-pg-mate-system-programmer","title":"GE Fanuc A08B-0031-B001 PG Mate System Programmer","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc A08B-0031-B001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA08B-0031-B001\u003c\/strong\u003e PG Mate System Programmer, operates as a dedicated hardware component for off-line program transfer and system parameter archiving within GE Fanuc CNC and PLC communication networks. Utilizing a 5 1\/4 floppy disk interface, the system reads, writes, and transfers ladder logic code and controller parameter sets across physical serial communication interfaces to target machine control units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA08B-0031-B001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e32.01 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Desk-Top\/Rack Console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e5 deg C to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eAC Line Driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProgram Writer \/ Serial Communication Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003e5 1\/4 inch Floppy Disk Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003ePG Mate System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe A08B-0031-B001 connects directly to machine controllers via point-to-point serial communication interfaces. Through specialized communication protocols, the system bypasses external backplane bus communication velocity limits to execute direct memory map transfers. Firmware flash compatibility across legacy controller mainboards allows system programmers to upload ladder execution routines and parameter matrices without risking code corruption or timing asynchronous faults during system initialization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the A08B-0031-B001 PG Mate system support live hot-swapping or connection while the machine tool is actively running an execution cycle?\u003c\/p\u003e\n\u003cp\u003eA: No, communication cables must be attached and secured while the controller is idle or de-energized. Connecting or disconnecting communication cables during active machining execution can disrupt serial handshake signals and trigger controller fault shutdowns.\u003c\/p\u003e\n\u003cp\u003eQ: How is chassis grounding managed to protect stored program transfers from electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: The main power feed must connect to a dedicated earth ground. Additionally, communication cables must utilize double-shielded twisted pair conductors with 360-degree shield bonding at the chassis frame to suppress high-frequency EMI noise generated by adjacent drive electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure main power switches on both the GE Fanuc controller and the A08B-0031-B001 unit are set to the OFF position prior to attaching any signal cabling.\u003c\/li\u003e\n\u003cli\u003eConnect the dedicated communication cable from the PG Mate serial port to the designated Honda or DB25 peripheral port on the host CNC\/PLC system.\u003c\/li\u003e\n\u003cli\u003eTighten all connector jack screws securely to maintain continuous ground continuity between cable shielding and the metal chassis frame.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming supply line matches the required AC line voltage ratings and is sourced from a clean, surge-protected industrial power branch.\u003c\/li\u003e\n\u003cli\u003ePower up the unit, insert a formatted 5 1\/4 floppy disk into the drive bay, and initiate system diagnostics to confirm communication handshake establishment before transferring files.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eCPUs, SCADA networks, HMIs, and peer PLCs via the backplane interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number structure for the \u003cstrong\u003eGE Fanuc IC697CMM742-HK\u003c\/strong\u003e decodes into specific hardware platform and revision attributes across the Series 90-70 system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC697\u003c\/strong\u003e: Designates the GE Fanuc Series 90-70 modular programmable controller hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMM\u003c\/strong\u003e: Identifies the communications module product category designed for dedicated network protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e742\u003c\/strong\u003e: Specifies the hardware design architecture incorporating 3 physical network ports (RJ-45, BNC, AUI) supporting 10 Mbps Ethernet communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHK\u003c\/strong\u003e: Indicates the specific hardware and firmware revision iteration implementing targeted component and backplane bus interfacing updates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697CMM742-HK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 29.2 cm x 22.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 A (+5 VDC), 0.5 A (+12 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eEthernet Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e3 (RJ-45 10BaseT, BNC 10Base2, 15-pin AUI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, SRTP, EGD, Modbus TCP, EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd\u003e4 (MODULE OK, LAN ONLINE, SERIAL ACTIVE, STATUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CMM742-HK\u003c\/strong\u003e module relies on standard VMEbus backplane interfacing to maintain backplane bus communication velocity across Series 90-70 rack assemblies. Preloaded firmware flash compatibility enables deterministic instruction decoding and real-time execution of configuration-based and logic-based Ethernet Global Data (EGD) protocols. The internal hardware architecture coordinates zero-latency network frame processing, maintaining high-density data throughput between the backplane logic and connected network interfaces while isolating backplane control cycles from network transmission jitter.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all three physical network ports (RJ-45, BNC, and AUI) on the IC697CMM742-HK be active at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The module contains hardware selection circuitry that limits active communication to one network port at a time depending on physical link detection and network topology setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the front-panel manual pushbutton on the IC697CMM742-HK?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The front-panel pushbutton allows maintenance personnel to initiate a local hardware restart and select diagnostic modes without disrupting main backplane rack power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported for the IC697CMM742-HK module in a Series 90-70 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Power to the Series 90-70 rack assembly must be disconnected prior to inserting or removing the module to avoid backplane bus electrical disturbances and potential physical component damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Disconnect primary cabinet power to the Series 90-70 rack prior to aligning or seating the IC697CMM742-HK module in the chassis slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Installation\u003c\/strong\u003e: Align the card edges with the plastic slot guides of a single available position in the Series 90-70 rack. Slide the module inward until backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Fastening\u003c\/strong\u003e: Engage the top and bottom retaining latches firmly over the rack frame flange, and torque the securing screws to 0.8 Nm (7 in-lb) to maintain mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Verify that the rack frame maintains a low-impedance ground connection to cabinet star ground using a minimum 14 AWG (2.5 mm sq) conductor. Ensure the module faceplate contacts the grounded chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Cabling\u003c\/strong\u003e: Connect the designated network cable (10BaseT RJ-45, 10Base2 coaxial with proper 50-ohm termination, or AUI transceiver harness) to the appropriate front port, ensuring proper strain relief and noise segregation from high-voltage AC lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45438292459635,"sku":"A08B-0031-B001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A08B-0031-B001_62f9fa3c-a9c3-46ed-b642-0d9a6b47f0b9.png?v=1788420794","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-a08b-0031-b001-pg-mate-system-programmer","provider":"DcsSupplier Limited","version":"1.0","type":"link"}