{"product_id":"ge-fanuc-ic610mdl182-series-one-relay-output-module","title":"GE Fanuc IC610MDL182 Series One Relay Output Module","description":"\u003cp\u003eConfigured for discrete load switching and electromechanical isolation in GE Fanuc Series One PLC backplanes, the \u003cstrong\u003eGE Fanuc IC610MDL182\u003c\/strong\u003e (\u003cstrong\u003eIC610MDL182\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution. This 16-point module interfaces internal logic states with external field actuators, routing switching currents through a removable terminal block while providing diagnostic status via front-panel LEDs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (0.77 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series One I\/O Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic-side powered via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Density\u003c\/td\u003e\n\u003ctd\u003e16 discrete relay points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eLED indicators per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wiring\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack Mountable Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Backplane Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC610MDL182 integrates into GE Fanuc Series One rack assemblies to establish high-density discrete switching channels. Internal logic isolation protects backplane bus communication velocity and prevents inductive noise spikes from disrupting CPU scan cycles. The module's hardware layout ensures firmware flash compatibility across standard Series One CPU platforms, maintaining deterministic network response and signal routing during high-duty electromechanical switching cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the wiring assembly be disconnected without unlanding individual field conductors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the IC610MDL182 features a removable terminal block, allowing complete replacement of the active module electronics without disconnecting landed field wires.\u003c\/p\u003e\n\u003cp\u003eQ: How are individual channel states monitored on the front panel?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 16 relay channels includes a surface-mount LED indicator that illuminates when the backplane drives the corresponding logic coil to an active state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion and Mechanical Latching\u003c\/strong\u003e: Align the module circuit board with the designated rack slot guides and press firmly until the backplane edge connector seats fully into the rack socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Wiring and Suppression\u003c\/strong\u003e: Land field load conductors onto the removable terminal block. Install external suppression devices (RC snubbers or varistors) across inductive AC loads to prevent contact arcing and high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Route AC load power conductors away from low-voltage DC communication cables inside cabinet wireways to minimize noise coupling into the backplane bus.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45491341885555,"sku":"IC610MDL182","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC610MDL182_Cocoai_1_4690387d-f888-4a75-94cf-6b51e6367240.jpg?v=1789351530","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic610mdl182-series-one-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}