{"product_id":"ge-fanuc-ic670mdl930-field-control-relay-output-module","title":"GE Fanuc IC670MDL930 Field Control Relay Output Module","description":"\u003cp\u003eConfigured for discrete output switching and load isolation in Field Control networks, the \u003cstrong\u003eGE Fanuc IC670MDL930\u003c\/strong\u003e (\u003cstrong\u003eIC670MDL930\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution. The unit delivers eight individually isolated channels consisting of six Form A (Normally Open) and two Form C (Normally Open\/Normally Closed) relay contacts to drive high-power AC and DC industrial field actuators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e313 mA (drawn from Bus Interface Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Isolated Channels (6 Form A, 2 Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 130 VDC, 0 to 265 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Load\u003c\/td\u003e\n\u003ctd\u003e16 A total across module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Load Rating\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 5-265 VAC \/ 5-30 VDC; 0.2 A at 31-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous \/ 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Suppression\u003c\/td\u003e\n\u003ctd\u003eOnboard RC Snubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDedicated Hardware Features\u003c\/h3\u003e\n\u003cp\u003eThe IC670MDL930 interfaces directly with the Field Control Bus Interface Unit (BIU) backplane to process 8 bits of discrete output data with deterministic response timing. Featuring fixed coil moving armature mechanics with silver alloy contacts, the module incorporates channel-to-channel isolation and onboard RC snubbers to suppress high-frequency voltage transients. High backplane bus communication velocity and full firmware flash compatibility allow reliable control execution without backplane noise contamination during heavy inductive load switching cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switching frequency for the relay outputs on the IC670MDL930 when driving inductive loads?\u003c\/p\u003e\n\u003cp\u003eA: When controlling inductive loads, each relay channel is limited to a maximum switching frequency of 20 cycles per minute to preserve contact life and prevent thermal overheating of the internal relay coils.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC670MDL930 supply power to the field loads directly from the backplane?\u003c\/p\u003e\n\u003cp\u003eA: No, the module's internal logic and relay coils draw 313 mA from the Bus Interface Unit, but field load current must be provided by an external user-supplied AC or DC power supply connected across the isolated output contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Disconnection:\u003c\/strong\u003e Disconnect main power to the Bus Interface Unit and isolate all external field load power sources before mounting or wiring the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Isolation:\u003c\/strong\u003e Wire field loads to the corresponding Form A (N.O.) or Form C (N.O.\/N.C.) terminals on the terminal block, ensuring that high-voltage AC cabling is kept separated from low-voltage bus communication wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSnubber Usage:\u003c\/strong\u003e Onboard RC snubbers provide transient protection for standard loads; for highly inductive loads (e.g., large solenoid coils or motor contactors), install external flyback diodes (DC) or varistors (AC) directly across the load terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the terminal block frame ground lug securely to the main system earth ground to ensure effective noise suppression and maximum galvanic isolation performance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45510488653939,"sku":"IC670MDL930","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC670MDL930_Cocoai_3a36edc8-a04f-4437-8b40-a9490d1988a8.jpg?v=1789634666","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic670mdl930-field-control-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}