{"product_id":"ge-fanuc-ic693alg392b-series-90-30-analog-output-module","title":"GE Fanuc IC693ALG392B Series 90-30 Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693ALG392B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693ALG392\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for converting digital controller commands into 8 high-resolution continuous voltage or current signals within Series 90-30 PLC backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693ALG392\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e8-Channel High-Resolution Analog Output Module, Revision B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693ALG392B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e36 mm x 130 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA at +5 VDC (backplane), 315 mA at +24 VDC (external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e0 to +10 VDC (unipolar), -10 to +10 VDC (bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 to 16 bits (range dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e8 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% FS (current), +\/-0.3% FS (voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt; 2 k-ohm; Current: \u0026lt; 750 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module optimizes I\/O density scaling by packing 8 independent high-resolution analog channels into a single backplane slot, maximizing panel space efficiency without compromising control precision. Backplane bus communication velocity ensures all 8 channels undergo deterministic scan updates within an 8 ms execution window. Configurable fault-mode parameters enable each channel to execute a hold-last-state or reset-to-zero command during CPU fault events, maintaining signal output safety and deterministic loop control.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external supply voltage is required to drive the 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eA: The analog output drive stages require an external user-supplied 24 VDC source connected to the module terminal block, drawing 315 mA under maximum output load conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide field fault detection for current loop wiring breaks?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When channels are configured for 4-20 mA operation, the module monitors physical loop continuity and reports open-wire faults to the CPU logic table.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for this module during active CPU execution?\u003c\/p\u003e\n\u003cp\u003eA: No. The Series 90-30 backplane requires complete de-energization before installing or removing modules to prevent physical backplane connector damage or unexpected logic fault trips.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate all main power sources to the PLC baseplate and external field power loops prior to module installation.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into its designated I\/O slot until the top and bottom backplane retaining clips snap locked.\u003c\/li\u003e\n\u003cli\u003eWire field actuators using twisted-pair shielded conductors, ensuring shield drain wires are tied directly to the central chassis ground bar.\u003c\/li\u003e\n\u003cli\u003eVerify external 24 VDC supply polarity on the terminal block prior to re-energizing the control system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503532662899,"sku":"IC693ALG392B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL940D2_Cocoai_fab43635-6ade-447b-8b60-256f6eb8df1b.jpg?v=1789529817","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic693alg392b-series-90-30-analog-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}