{"product_id":"ge-fanuc-ic693mdl310-series-90-30-output-module","title":"GE Fanuc IC693MDL310 Series 90-30 Output Module","description":"\u003cp\u003eConfigured for discrete AC switching in Series 90-30 PLC platforms, the \u003cstrong\u003eGE Fanuc IC693MDL310\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL310\u003c\/strong\u003e Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 Module Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Backplane Bus Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e12 Output Points (Two Isolated Groups, 6 Points per Group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Class\u003c\/td\u003e\n\u003ctd\u003ePLC Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Fanuc Technical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Transfers digital output bit states directly across the Series 90-30 backplane bus, maintaining microsecond-level register updates without scan-cycle synchronization delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Integrates 12 discrete 120 VAC output circuits split into two isolated 6-point banks into a single slot format to maximize panel control density.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693MDL310 output module be inserted or removed while the Series 90-30 rack is powered? A: No. The IC693MDL310 does not support hot-swapping; backplane logic power must be isolated prior to removing or inserting the module to prevent CPU fault trips or hardware damage.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 12 AC output points electrically isolated from one another on the IC693MDL310? A: The 12 outputs are divided into two independent isolated groups containing 6 output points each, allowing operation across distinct power phases or separate field circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What is the continuous current rating for each output point on the IC693MDL310? A: Each individual output point is rated for a maximum continuous current of 0.5 A at 120 VAC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate primary system line power and external field power loops supplying the module terminal block prior to installation or wiring.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the target rack slot guide rails and press firmly until the top and bottom backplane connectors fully seat.\u003c\/li\u003e\n\u003cli\u003eRoute field load conductors separately from low-voltage communication lines to minimize high-frequency electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that field fuse protection is rated appropriately for 0.5 A continuous current per channel to prevent conductor overload during short-circuit events.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45338879918195,"sku":"IC693MDL310","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-10_15-25-56_b280b413-0c69-486f-b9be-ea6b7658262c.png?v=1786346817","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic693mdl310-series-90-30-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}