{"product_id":"ge-fanuc-ic693mdl740j-series-90-30-digital-output-module","title":"GE Fanuc IC693MDL740J Series 90-30 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL740J\u003c\/strong\u003e is a 16-point positive logic sourcing output module designed for the Series 90-30 PLC platform. It provides two groups of eight DC output channels, each rated at 0.5 A, for controlling external loads through 12\/24 VDC switching circuits. Front-panel LED indicators display individual channel activity and module operating status.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL740J uses a positive logic sourcing circuit to supply current from the positive DC power bus to connected field devices. Its 16 output points are divided into two groups, with eight channels and a common power connection per group.\u003c\/p\u003e\n\u003cp\u003eThe module supports compatible DC loads, including relays, contactors, solenoids, pilot lamps, buzzers, horns, and motor starters. Each output channel supports a maximum load current of 0.5 A, while the specified common current limit must also be observed when multiple outputs operate simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSwitching Characteristics and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output circuit has a maximum voltage drop of 1 V and an off-state leakage current of 1 mA. Both ON and OFF response times are specified at a maximum of 2 ms, allowing the module to respond to PLC output commands with short switching delays.\u003c\/p\u003e\n\u003cp\u003eThe specified inrush current is 4.78 A for 10 ms. The module does not include internal output fuses, so external circuit protection should be selected according to the connected load and field wiring requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indication and PLC Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFront-panel LEDs provide individual output channel indications and module operating-status information. These indicators help maintenance personnel identify output activity and investigate potential field circuit or load-related issues.\u003c\/p\u003e\n\u003cp\u003eThe IC693MDL740J is designed for GE Fanuc Series 90-30 PLC systems and can be installed in an available slot of a 5-slot or 10-slot baseplate. The total number of supported output modules depends on available rack positions and the controller's memory capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL740J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Circuit Type\u003c\/td\u003e\n\u003ctd\u003ePositive Logic, Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Groups\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels per Group\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC (+20%, -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Common\u003c\/td\u003e\n\u003ctd\u003e2 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4.78 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON Response Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF Response Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Draw\u003c\/td\u003e\n\u003ctd\u003e110 mA from 5 VDC backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Input Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eIndividual channel LEDs and module status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Output Fusing\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-30 PLCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Compatibility\u003c\/td\u003e\n\u003ctd\u003e5-slot and 10-slot Series 90-30 baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lb (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Repair\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC693MDL740J belongs to a discontinued product family. DcsSupplier Limited specializes in obsolete industrial automation components and can assist with sourcing surplus or refurbished replacement units, subject to availability.\u003c\/p\u003e\n\u003cp\u003eRepair requests can also be made for existing modules. Before ordering a replacement, verify the complete part number, output configuration, electrical ratings, and Series 90-30 baseplate requirements against the installed PLC system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the output configuration of the IC693MDL740J?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It has 16 positive logic sourcing outputs arranged in two groups of eight channels. Each channel supports up to 0.5 A, with a common current limitation that must be observed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of field devices can the IC693MDL740J control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It can control compatible 12\/24 VDC loads, including relays, contactors, solenoids, pilot lamps, buzzers, horns, and motor starters. Load current and inrush requirements must remain within the module's specified limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC693MDL740J include internal fuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module does not have internal output fusing. External fuses should be considered to protect the output circuits and connected field wiring.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67246178795635,"sku":"IC693MDL740J","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL752D2_Cocoai_ebc1c87b-e243-40f4-97ad-2a39ddbeb308.jpg?v=1794992728","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic693mdl740j-series-90-30-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}