{"product_id":"ge-fanuc-ic693mdl740k-series-90-30-digital-output-module","title":"GE Fanuc IC693MDL740K Series 90-30 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL740K\u003c\/strong\u003e is a 16-point positive logic DC output module for the Series 90-30 PLC platform. It uses a sourcing output circuit to switch external DC loads, with two groups of eight channels and a rated output current of 0.5 A per point. Front-panel LED indicators provide individual channel status and module operating-state indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL740K provides 16 sourcing output points arranged in two electrically grouped sections, each containing eight channels. Each group has a common power connection. The sourcing circuit supplies current from the positive DC bus to connected loads, which are connected between the output terminals and the negative power bus.\u003c\/p\u003e\n\u003cp\u003eThe module supports 12\/24 VDC nominal operation, making it suitable for compatible DC loads such as interposing relays, contactors, solenoids, pilot lamps, and motor starters. Each output point supports up to 0.5 A, subject to the 2 A maximum current limit per common.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Protection and Switching Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has a maximum output voltage drop of 1 V and an off-state leakage current of 1 mA. Both ON and OFF response times are specified at a maximum of 2 ms, defining the switching delay between the commanded output state and the electrical response.\u003c\/p\u003e\n\u003cp\u003eThe module does not include internal output fusing. External fuses should therefore be considered when designing load circuits, with ratings selected according to the connected loads and wiring requirements. The specified inrush current is 4.78 A for 10 ms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indication and PLC Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFront-panel LEDs indicate the individual output channel states and the module's operational status. These indicators help maintenance personnel identify commanded output activity and assist with troubleshooting field wiring and connected loads.\u003c\/p\u003e\n\u003cp\u003eThe IC693MDL740K is specified for GE Fanuc Series 90-30 PLC systems and can be installed in an available slot of a 5-slot or 10-slot baseplate. The number of modules supported in a rack depends on the available slots and the controller's memory capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL740K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Circuit Type\u003c\/td\u003e\n\u003ctd\u003ePositive Logic, Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Groups\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels per Group\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC (+20%, -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Common\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4.78 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON Response Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF Response Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Draw\u003c\/td\u003e\n\u003ctd\u003e110 mA from 5 VDC backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Input Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eIndividual channel LEDs and module status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Output Fusing\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-30 PLCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Compatibility\u003c\/td\u003e\n\u003ctd\u003e5-slot and 10-slot Series 90-30 baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lb (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Repair\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC693MDL740K has been discontinued by the manufacturer. DcsSupplier Limited specializes in obsolete industrial automation components and can assist with sourcing surplus or refurbished units, subject to availability.\u003c\/p\u003e\n\u003cp\u003eRepair services can also be requested for existing units. When replacing an installed module, verify the complete part number, output configuration, electrical ratings, and Series 90-30 baseplate requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of output does the IC693MDL740K provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 16 positive logic sourcing DC outputs. Each channel supplies current to the connected load from the positive DC power bus, with a maximum rated current of 0.5 A per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IC693MDL740K drive relays and solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It can operate compatible 12\/24 VDC loads, including relays, contactors, solenoids, and indicator lamps. Each output is limited to 0.5 A, and the total current per common must not exceed 2 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC693MDL740K have internal output fuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module does not include internal output fusing. External circuit protection should be selected according to the connected load and field wiring requirements.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67246159495283,"sku":"IC693MDL740K","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL752D_Cocoai_0cf6c17c-5305-4a7d-b42b-99f88c8d60a7.jpg?v=1794992728","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic693mdl740k-series-90-30-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}