{"product_id":"ge-fanuc-ic693mdl940d-series-90-30-relay-output-module","title":"GE Fanuc IC693MDL940D Series 90-30 Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL940D\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module utilized to execute discrete load switching and output isolation across Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 40 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA at +5 VDC (backplane bus), 135 mA at +24 VDC Relay (backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points (4 isolated groups of 4 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC, 5 to 250 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per point, 4 A maximum per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS logic-to-field, 500 V RMS group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Architecture \u0026amp; I\/O Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Series 90-30 backplane bus, utilizing optocoupler isolation to maintain deterministic backplane bus communication velocity and system logic integrity. Field output control signals pass across high-speed optical barriers rated for 1500 V RMS isolation to protect backplane microcomputers from external field noise and switching spikes. The 16 discrete channels are structured into four independent isolated groups, providing I\/O density scaling and galvanic separation between isolated external AC and DC load circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC693MDL940D module contain internal protection fuses for individual relay output channels?\u003c\/p\u003e\n\u003cp\u003eA: No. The module contains no internal fuses. External current-limiting fuses must be wired into each output point circuit or group common to protect relay contacts against overcurrent faults.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for the IC693MDL940D hardware module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 7 mA from the internal +5 VDC logic bus and 135 mA from the +24 VDC relay power supply bus during active output state conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main supply power to the baseplate and field circuits prior to mounting or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit board edge with the top and bottom card guides of the selected baseplate I\/O slot, pushing firmly until the module locks into the backplane connector.\u003c\/li\u003e\n\u003cli\u003eWire the field devices to the removable 20-terminal block, ensuring output point current does not exceed 2 A per point or 4 A per common terminal.\u003c\/li\u003e\n\u003cli\u003eRoute AC load lines, DC signal wiring, and communication cables in separate grounded metallic conduits to eliminate inductive coupling and electrical interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503482560627,"sku":"IC693MDL940D","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL940D3_Cocoai.jpg?v=1789529636","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic693mdl940d-series-90-30-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}