{"product_id":"ge-fanuc-ic754vsb06mtd-hmi-operator-interface","title":"GE Fanuc IC754VSB06MTD HMI Operator Interface","description":"\u003cp\u003eConfigured for graphic visualization and touch-input control in QuickPanel View, Basic networks, the \u003cstrong\u003eGE Fanuc IC754VSB06MTD\u003c\/strong\u003e (\u003cstrong\u003eIC754VSB06MTD\u003c\/strong\u003e Human Machine Interface) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC754VSB06MTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 6 inch chassis parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard logic bus power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (12 - 30 VDC allowable input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Parameters\u003c\/td\u003e\n\u003ctd\u003e6 inch Passive FSTN Monochrome, 320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor \u0026amp; Clock\u003c\/td\u003e\n\u003ctd\u003eIntel XScale PXA255 running at 200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Architecture\u003c\/td\u003e\n\u003ctd\u003e16 MB Flash, 16 MB DRAM, 512 KB ROM Boot loader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Input\u003c\/td\u003e\n\u003ctd\u003e12 bit analog resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003e1 x Ethernet, 1 x Serial EIA232C\/EIA485 (DP25S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Construction\u003c\/td\u003e\n\u003ctd\u003eRound Valox 3706 bezel with Lexan HP60 membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows CE Operating System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Driver Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e The module maps multi-touch position variables through a 12 bit resistive matrix, translating mechanical matrix force vectors directly into discrete integer registers within connected programmable controller environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility:\u003c\/strong\u003e System logic executes over a 16 MB onboard Flash area, aligning target visualization runtimes directly with the system boot loader structure to retain configurations across thermal and power interruption states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary communication link options available on this interface hardware? A: The physical housing integrates one Ethernet interface and one combined Serial EIA232C\/EIA485 port mapped to a DP25S connector, supporting RS232 and RS485 communication protocols via an HMI-CAB-CS2 cable.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input power circuit tolerate variance from the baseline voltage specification? A: Yes, the system functions via a nominal 24 VDC input but contains power conditioning circuits rated to accept continuous operational deviations spanning from 12 to 30 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Bezel Sealing:\u003c\/strong\u003e Insert the round Valox 3706 bezel directly into the panel cutout. Tighten all rear mounting retaining screws progressively to guarantee even sealing tension, preventing atmospheric contaminants from penetrating the Lexan HP60 front membrane layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable Isolation routing:\u003c\/strong\u003e Lay out the HMI-CAB-CS2 communication cable inside dedicated low-voltage wire paths. Maintain separation from three-phase AC power routing and high-frequency inverter outputs to limit electromagnetic cross-talk into the serial transceivers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Ground Terminal Grounding:\u003c\/strong\u003e Establish a low-impedance connection by attaching a heavy-gauge copper earthing conductor from the terminal ground stud directly to the main machinery enclosure backplane prior to energizing the input power terminals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45256547205235,"sku":"IC754VSB06MTD","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-18_15-02-37_f8a40342-980e-498c-b91c-19b26b1a4be0.png?v=1784256170","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-ic754vsb06mtd-hmi-operator-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}