{"product_id":"ge-fanuc-qpi21100e2p-quickpanel-operator-interface-terminal","title":"GE Fanuc QPI21100E2P QuickPanel Operator Interface Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc QPI21100E2P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eQPI21100\u003c\/strong\u003e Operator Interface Terminal, operates as a dedicated hardware component for real-time visualization and localized machine control execution within industrial control network platforms. It handles human-machine interaction by rendering system telemetry and accepting operator inputs over serialized backplane bus pathways. Operating on an input voltage rating of 120 VAC, this ruggedized unit replaces hardwired panel components, delivering high-contrast visual telemetry via an 8.9-inch amber electroluminescent display engine with a graphic resolution of 640 x 400 pixels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI21100E2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Total Control Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard panel housing weight matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.79 in x 8.50 in x 2.23 in (274 mm x 216 mm x 56.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eAmber High Intensity Electroluminescent (EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Size\u003c\/td\u003e\n\u003ctd\u003e8.9 inches diagonal (Display area 10.2 in W x 7.92 in H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraphic Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 400 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB Flash EPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT (Operator Interface Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe unit relies on high-speed backplane bus communication velocity and deterministic serial polling protocols to synchronize bitmask registers with host programmable controllers. Interface options include a dedicated serial I\/O port and a project download port for field updates. Firmware flash compatibility checks ensure project memory integrity within the integrated 2 MB Flash EPROM storage during software compile and download cycles executed via QuickDesigner. High-density I\/O register mapping allows real-time data transfers across PLC communications without introducing scanning delays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What operational advantage does the amber electroluminescent (EL) display provide?\u003c\/p\u003e\n\u003cp\u003eA: The high-intensity amber EL display maintains visual legibility in extremely bright industrial environments where standard display types suffer from glare and contrast degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the unit connect to all PLC network communication protocols?\u003c\/p\u003e\n\u003cp\u003eA: The terminal interfaces with major programmable logic controllers via its serial I\/O connection, though certain advanced network protocols are restricted to larger screen platform models.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePrepare an enclosure cutout conforming to the specified mounting depth of 2.23 inches (56.5 mm) and outer bezel profile. Clamp the unit securely to ensure full compression of the NEMA Type 4X\/12 and IP65 perimeter sealing gasket. Bring 120 VAC main power wiring through isolated conduit pathways separate from low-voltage DC signals and serial communication cables to suppress electromagnetic interference. Connect a direct low-impedance protective earth (PE) ground lead to the main chassis earth stud. Shielded serial cables must be grounded at a single termination point to prevent destructive ground loop currents.\u003c\/p\u003e\n\u003cp\u003ee and serial communication channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI-3D200-S2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Commercial OEM Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.4 inch Display Diagonal (Standard Housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C (Standard Operating Limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal Input Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eStandard Color LCD Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc QPI-3D200-S2P module relies on backplane bus communication velocity and firmware flash compatibility to deliver consistent data synchronization with host control units. High bus throughput minimizes protocol conversion latencies during intensive graphics rendering, preventing input delay or dropped operator control frames during alarm bursts. Internal non-volatile flash memory retains compiled application screens and communication drivers, preserving configuration integrity across complete system power drops without relying on external battery backup.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary electrical power termination parameters for this unit? A: The display terminal operates on a nominal 24 VDC external supply input. Power wiring must be executed using dedicated twisted-pair conductors routed away from high-voltage AC conductors to limit supply ripple and electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eQ: How is front panel ingress protection preserved during cabinet mounting?\u003c\/p\u003e\n\u003cp\u003eA: Environmental sealing up to NEMA Type 4X\/12 and IP65 standards is maintained by seating the synthetic elastomeric gasket flush against the panel cutout and securing all mounting brackets with uniform clamping force.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify cabinet cutout dimensions prior to mechanical insertion of the chassis. Position the synthetic perimeter gasket flush against the panel cutout lip to preserve NEMA Type 4X\/12 and IP65 ingress protection against dust and liquid infiltration. Tighten all mounting clips in a cross-corner alternating sequence to exert uniform pressure along the bezel frame, preventing screen matrix distortion or touch grid alignment shift.\u003c\/p\u003e\n\u003cp\u003eRoute low-voltage 24 VDC power cables and serial\/network communication lines through dedicated wiring channels physically segregated from high-voltage AC power conductors and motor drive outputs. Ensure communication signal shields are bonded to a low-impedance earth ground at a single node to eliminate ground loop currents that could destabilize serial transceiver circuitry.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45410549923955,"sku":"QPI21100E2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPJ-2D100-L2P_2_cabfd486-e98f-434e-a3c8-4dd4a170a826.png?v=1787796396","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-qpi21100e2p-quickpanel-operator-interface-terminal","provider":"DcsSupplier Limited","version":"1.0","type":"link"}