{"product_id":"ge-fanuc-qpi31200c2p-quickpanel-hmi-module","title":"GE Fanuc QPI31200C2P QuickPanel HMI Module","description":"\u003cp\u003eConfigured for real-time process visualization and operator interface execution in GE Fanuc control networks, the \u003cstrong\u003eGE Fanuc QPI31200C2P\u003c\/strong\u003e (\u003cstrong\u003eQPI31200C2P\u003c\/strong\u003e QuickPanel HMI) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI31200C2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Total Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg (7.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e317 mm x 243 mm x 85 mm (12.48 in x 9.57 in x 3.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e10.4 in TFT Color Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e2 MB Flash EPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEMA Rating\u003c\/td\u003e\n\u003ctd\u003eType 4X \/ 12 (IP65 front panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Deterministic Network Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Executes deterministic data exchange across serial and network communications, maintaining update cycle synchronization with connected programmable logic controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Integrated 2 MB Flash EPROM non-volatile memory validates project file downloads from QuickDesigner Version 3.7 and prevents memory corruption during unpowered states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Provides high-density operator touch-target scaling across a 640 x 480 resolution graphic matrix, reducing panel space footprint while centralizing field telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What environmental protection rating does the front enclosure provide when panel-mounted?\u003c\/p\u003e\n\u003cp\u003eA: The front display panel is rated NEMA Type 4X\/12 and IP65, providing protection against dust ingress, splashed liquids, direct water spray, and corrosive environments.\u003c\/p\u003e\n\u003cp\u003eQ: How is project memory retained inside the unit during main power loss?\u003c\/p\u003e\n\u003cp\u003eA: Application runtime files and graphics are stored in 2 MB Flash EPROM non-volatile memory, which retains project data indefinitely without relying on internal battery power.\u003c\/p\u003e\n\u003cp\u003eQ: Can the display resolution be modified within the QuickDesigner programming software?\u003c\/p\u003e\n\u003cp\u003eA: No, the hardware rendering resolution is fixed at 640 x 480 pixels. Screen projects developed in QuickDesigner Version 3.7 must match this target display resolution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout and Mounting\u003c\/strong\u003e: Prepare a clean panel cutout matching the unit dimensions. Insert the HMI unit from the front of the enclosure and tighten all rear panel mounting clamps evenly to compress the front gasket for NEMA 4X\/12 sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Connect the dedicated earth terminal on the unit chassis to the cabinet earth ground bar using a short, low-impedance grounding strap. Ensure all communication cable shields ground at a single panel point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring\u003c\/strong\u003e: Connect a dedicated 120 VAC power line to the input terminals. Wire input conductors in compliance with local electrical codes and route through a dedicated circuit breaker or fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit and Signal Separation\u003c\/strong\u003e: Maintain physical separation between 120 VAC power conductors and low-voltage serial or fieldbus communication lines within cabinet wireways to minimize electromagnetic noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45328696049779,"sku":"QPI31200C2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-07_13-37-03_1200x1200_18c6f2fe-ade3-44a7-a00d-dec8bfe207a6.jpg?v=1786082193","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-qpi31200c2p-quickpanel-hmi-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}