{"product_id":"ge-fanuc-qpj-2d101-s2p-quickpanel-jr-series-operator-interface","title":"GE Fanuc QPJ-2D101-S2P QuickPanel Jr. Series Operator Interface","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc QPJ-2D101-S2P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eQPJ-2D101-S2P\u003c\/strong\u003e Operator Interface, operates as a dedicated hardware component for real-time visualization and direct machine-level interaction within industrial control platforms. The unit establishes deterministic human-machine interface controls without software execution latency, facilitating real-time parameter monitoring, alarm acknowledgment, and discrete operator override commands over direct backplane and serial communication channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPJ-2D101-S2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Commercial OEM Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.64 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.7 inch Display Diagonal (Standard Housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C (Standard Operating Limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal Input Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eMonochrome LCD Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc QPJ-2D101-S2P module relies on backplane bus communication velocity and firmware flash compatibility to deliver consistent data synchronization with host control units. High bus throughput minimizes protocol conversion latencies during intensive graphics rendering, preventing input delay or dropped operator control frames during alarm bursts. Internal non-volatile flash memory retains compiled application screens and communication drivers, preserving configuration integrity across complete system power drops without relying on external battery backup.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary power termination practices for the 24 VDC input logic?\u003c\/p\u003e\n\u003cp\u003eA: The panel operates on a nominal 24 VDC external supply. Wiring must be installed using dedicated conductors routed separately from high-voltage AC lines to prevent power ripples from affecting the internal display controller logic.\u003c\/p\u003e\n\u003cp\u003eQ: How is front panel environmental sealing preserved in dusty or wet environments?\u003c\/p\u003e\n\u003cp\u003eA: Ingress protection up to NEMA Type 4X\/12 and IP65 standards is maintained by seating the continuous perimeter gasket flush against the panel cutout and tightening all mounting clips evenly to prevent screen frame twisting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify panel cutout dimensions prior to final mechanical insertion. Position the synthetic rubber sealing gasket flush against the panel rim to maintain NEMA Type 4X\/12 and IP65 seal integrity against dust and liquid ingress. Tighten all mounting clips in a cross-corner alternating sequence to exert even pressure along the front bezel and prevent touchscreen grid warping.\u003c\/p\u003e\n\u003cp\u003eRoute all low-voltage 24 VDC power and communication cabling in separate wiring channels away from high-voltage AC conductors and drive outputs. Ensure shielding on serial and network communication lines is bonded to a low-impedance single-point earth ground to eliminate electrical ground loop noise and prevent transceiver circuit faults.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45401281495155,"sku":"QPJ-2D101-S2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPK-3D200-L2P_e2bed8a3-9a6f-4c12-819a-71102dc0ae31.png?v=1787727608","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-qpj-2d101-s2p-quickpanel-jr-series-operator-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}