{"product_id":"ge-fanuc-qpl2d200c2p-quickpanel-hmi-modules","title":"GE Fanuc QPL2D200C2P QuickPanel HMI Modules","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc QPL2D200C2P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eQPL2D200C2P\u003c\/strong\u003e Touch Screen Informational Display, operates as a dedicated hardware component for operator interface control and visual process monitoring within GE Fanuc automation networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPL2D200C2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Total Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Commercial Origin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.1 in diagonal screen size (Viewing Area: 9.8 in W x 7.35 in H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial (0 deg C to 50 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Range: 20.4 VDC to 27.6 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e12 in TFT Color LCD (8 solid \/ 8 flashing colors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e600 x 800 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Immunity Hold\u003c\/td\u003e\n\u003ctd\u003eUp to 20 ms power outage immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eBackplane bus communication velocity Licences and industrial network cycle determinism define the integration performance of the host control system. High-density I\/O routing paired with validated firmware flash compatibility prevents logic processing bottlenecks between the PLC central processing unit and operator interface hardware. Proper channel-to-channel isolation limits field ground loop interference, ensuring predictable data execution across continuous industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the permissible input voltage range for field power wiring connected to the unit?\u003c\/p\u003e\n\u003cp\u003eA: The nominal rating is 24 VDC, with an acceptable operating intake range of 20.4 VDC to 27.6 VDC. The unit maintains continuous operation through brief power supply drops of up to 20 ms.\u003c\/p\u003e\n\u003cp\u003eQ: What are the front panel ingress protection ratings for panel cutout mounting?\u003c\/p\u003e\n\u003cp\u003eA: When correctly mounted into an enclosure using the factory gasket, the front bezel meets NEMA Type 4X\/12 and IP65 standards for protection against liquid splash and dust ingress.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that external 24 VDC power source supplies are disconnected before wiring terminal connections.\u003c\/li\u003e\n\u003cli\u003eCut enclosure opening to match standard 12.1 in unit mounting templates, ensuring seal contact around the NEMA 4X\/12 IP65 perimeter.\u003c\/li\u003e\n\u003cli\u003eGround the unit chassis directly to the enclosure backplate using a low-impedance copper grounding strap.\u003c\/li\u003e\n\u003cli\u003eAllow a minimum of 50 mm clearance around all outer cooling vents to prevent internal thermal degradation during continuous operation.\u003c\/li\u003e\n\u003cli\u003eSecure all communication cables to interface ports using thumbscrews to mitigate signal interruption from mechanical vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45396891664499,"sku":"QPL2D200C2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPL2D200C2P_3b87dbf2-31dc-480c-a587-e015f78c68e7.png?v=1787641079","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-qpl2d200c2p-quickpanel-hmi-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}