{"product_id":"ge-ic200mdl650e-versamax-digital-input-module","title":"GE IC200MDL650E VersaMax Digital Input Module","description":"\u003cp\u003eConfigured for discrete signal sensing in GE VersaMax PLC platforms, the \u003cstrong\u003eGE IC200MDL650E\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL650\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. This module receives external 24 VDC discrete states from field devices across 16 independent channels and converts them into optical logic states for process controller execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL650E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg (0.40 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 cm x 6.5 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W typical (24 VDC from backplane, 19.2 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eVersaMax Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Sink\/Source Selectable per Group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State \/ Off-State Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 15 VDC On \/ \u0026lt; 5 VDC Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current \/ Impedance\u003c\/td\u003e\n\u003ctd\u003e7 mA typical at 24 VDC \/ 3.4 k-ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Response Time\u003c\/td\u003e\n\u003ctd\u003e4 ms ON \/ 4 ms OFF typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003eOptocoupler 1500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Interface\u003c\/td\u003e\n\u003ctd\u003e1 x 20-pin Removable Screw Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL650E interfaces directly with the VersaMax I\/O backplane bus through its carrier base, transferring opto-isolated channel states to the central processor within a standard 4 ms response frame. Backplane bus communication velocity depends on deterministic logic scan execution, where integrated voltage regulation and EMI filtering prevent bus noise coupling during state switching. Maintaining proper firmware flash compatibility across the host CPU or network interface unit ensures structured bit-mapping over the backplane without channel timing jitter or data framing errors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC200MDL650E module be inserted into or removed from the carrier base while backplane power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No, backplane power and external 24 VDC field power must be de-energized prior to inserting or removing the module to prevent electrical transients and backplane communication faults.\u003c\/p\u003e\n\u003cp\u003eQ: How are sink and source wiring configurations selected for the input channels?\u003c\/p\u003e\n\u003cp\u003eA: Common terminals are assigned across two groups of 8 channels on the 20-pin removable terminal block, allowing independent sink or source wiring by referencing common to 24 VDC positive or DC return.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all system power sources, including VersaMax backplane supply and field input power, are fully isolated before installing or servicing the module.\u003c\/li\u003e\n\u003cli\u003eSnap the carrier base onto a standard DIN rail, ensuring the grounding tab makes firm metallic contact with the grounded mounting rail.\u003c\/li\u003e\n\u003cli\u003eAlign the IC200MDL650E module with the carrier guide slots and press firmly until the retaining latches click fully into place.\u003c\/li\u003e\n\u003cli\u003eWire field input field signals to the 20-pin removable terminal block, keeping 24 VDC signal runs segregated from high-voltage AC conductors.\u003c\/li\u003e\n\u003cli\u003eApply backplane and field power, then observe channel LEDs to confirm valid signal recognition during input state transitions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEO Title\u003c\/td\u003e\n\u003ctd\u003eIC200MDL650E GE VersaMax Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeta Description\u003c\/td\u003e\n\u003ctd\u003eBuy IC200MDL650E Brand New GE VersaMax 16-channel 24 VDC digital input module in Original Stock. Global Shipping available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTags\u003c\/td\u003e\n\u003ctd\u003eDigital Input Modules, GE VersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003e VersaMax Thermocouple Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-resolution temperature and millivolt signal processing in GE VersaMax PLC platforms, the \u003cstrong\u003eGE IC200ALG630-DB\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG630\u003c\/strong\u003e Thermocouple Analog Input Module) provides direct physical\/electrical execution. This 7-channel module interfaces directly with millivolt sources and thermocouple types J, K, T, S, and R, converting physical sensor voltages into digital data representations for execution by the central CPU.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG630-DB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (5.51 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact VersaMax Module Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA max @ 5 VDC \/ 125 mA max @ 3.3 VDC (Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e7 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input Ranges\u003c\/td\u003e\n\u003ctd\u003eThermocouple types J, K, T, S, R, and mV inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits plus sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy @ 25 deg C\u003c\/td\u003e\n\u003ctd\u003eVoltage: ±0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status Indicators\u003c\/td\u003e\n\u003ctd\u003eOK LED (Green: Power Normal; Amber: Module Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG630-DB executes high-speed data transmission over the VersaMax backplane bus, drawing up to 125 mA at 5 VDC and 125 mA at 3.3 VDC to support its 15-bit plus sign analog-to-digital processing engine. Firmware flash compatibility within the bus interface controller maintains synchronized data framing during CPU I\/O scan sweeps, ensuring low latency during cold junction compensation calculations and millivolt conversion loops. Integrated backplane driver isolation suppresses high-frequency bus noise, preserving 0.15% temperature measurement accuracy across active network channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What does an amber \"OK\" LED indicator signify on the IC200ALG630-DB?\u003c\/p\u003e\n\u003cp\u003eA: An amber \"OK\" status LED indicates an active module fault condition, such as a hardware diagnostic failure, continuous open-wire detection, or configuration error on one of the thermocouple input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels on the IC200ALG630-DB be configured for non-thermocouple millivolt inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, individual channels can be programmed to \"none\" in software, allowing the hardware to accept direct low-voltage DC millivolt input signals instead of linearized thermocouple curves.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCompletely isolate and de-energize backplane power and external instrument loop sources before installing or servicing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the IC200ALG630-DB module housing with the VersaMax I\/O carrier base and press firmly until the locking tabs snap into place.\u003c\/li\u003e\n\u003cli\u003eWire thermocouple extension wires directly to the carrier terminal block. Ensure correct polarity matching and isolate wire shields to prevent stray voltage potential across thermocouple leads.\u003c\/li\u003e\n\u003cli\u003eKeep thermocouple signal cabling physically separated from high-voltage motor power leads and AC switching circuits to prevent electromagnetic noise induction.\u003c\/li\u003e\n\u003cli\u003eApply backplane power and verify that the \"OK\" LED illuminates steady green before initiating process control routines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":48385066500211,"sku":"IC200MDL650E","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC660EBD1202_Cocoai_95c70f11-04e8-42f5-80b6-a29172c4a08e.jpg?v=1789962826","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic200mdl650e-versamax-digital-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}