{"product_id":"ge-ic200udd110-ba-versamax-micro-controller","title":"GE IC200UDD110-BA VersaMax Micro Controller","description":"\u003cp\u003eConfigured for discrete I\/O execution and local sequence control in VersaMax system architecture, the \u003cstrong\u003eGE IC200UDD110-BA\u003c\/strong\u003e (\u003cstrong\u003eIC200UDD110\u003c\/strong\u003e Micro Controller) provides direct physical\/electrical execution. It handles field digital signals and executes real-time logic routines without external processing overhead.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDD110-BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.77 lbs (0.35 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Micro Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Supply Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Discrete Points\u003c\/td\u003e\n\u003ctd\u003e28 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Inputs at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Current Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Outputs at 24 VDC, 1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Outputs at 24 VDC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates non-volatile flash memory for logic program storage and runtime firmware execution. Firmware integrity validation occurs during startup initialization to prevent execution errors under transient power conditions. High-density I\/O integration within a single physical housing reduces backplane communication delays. Internal signal conversion registers update synchronously with CPU scanning cycles, maintaining deterministic execution across all 28 discrete channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum output current rating for the discrete channels on this unit?\u003c\/p\u003e\n\u003cp\u003eA: The controller features 12 total discrete 24 VDC outputs split into two current ratings: 6 channels support up to 1.0 A continuous load per point, while the remaining 6 channels support up to 0.5 A continuous load per point.\u003c\/p\u003e\n\u003cp\u003eQ: How does the controller respond to power interruptions during operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit utilizes integrated non-volatile flash memory to retain logic routines and configuration parameters without requiring battery backup. Upon restoration of 24 VDC supply voltage, the controller performs internal diagnostic self-tests before resuming program execution.\u003c\/p\u003e\n\u003cp\u003eQ: Can this unit expand beyond its built-in 28 I\/O points?\u003c\/p\u003e\n\u003cp\u003eA: Yes, expansion modules can interface via the local expansion bus interface, scaling the discrete and analog I\/O capacity while operating under the primary micro controller logic engine.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the unit securely on standard 35 mm DIN-rail hardware or direct panel surface mounting points. Maintain a minimum 50 mm clearance around ventilation slots to allow passive convection cooling.\u003c\/li\u003e\n\u003cli\u003eConnect the primary power source using 24 VDC shielded power wiring. Verify polarity prior to energizing to prevent input stage fuse damage.\u003c\/li\u003e\n\u003cli\u003eTerminate signal lines at the removable terminal blocks. Keep 24 VDC input wiring physically segregated from high-voltage AC power lines to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect the signal shield ground directly to a low-impedance functional earth (FE) bus bar. Maintain a single-point grounding scheme to prevent ground loop circulating currents.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45421832700019,"sku":"IC200UDD110-BA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC200PWR102D_20.png?v=1788143987","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic200udd110-ba-versamax-micro-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}