{"product_id":"ge-ic200uex009-a-expansion-modules","title":"GE IC200UEX009-A Expansion Modules","description":"\u003cp\u003eConfigured for expansion of I\/O processing capabilities in GE VersaMax PLC platforms, the \u003cstrong\u003eGE IC200UEX009-A\u003c\/strong\u003e (\u003cstrong\u003eIC200UEX009\u003c\/strong\u003e Micro Expansion Unit) provides direct physical\/electrical execution. The module processes 8 discrete input channels rated at 120 VAC and drives 6 relay output channels (2 rated at 10 A and 4 rated at 2 A) via an integrated 120\/240 VAC power supply.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEX009-A (Base: IC200UEX009)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.15 lbs (0.52 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Micro Expansion Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eIntegrated 120\/240 VAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e14 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Channels at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Relay Outputs (2 Channels at 10 A, 4 Channels at 2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eVersaMax PLC Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200UEX009-A scales system I\/O density by interfacing directly with the primary VersaMax CPU across the expansion bus. Onboard power conversion optics and isolation barriers decouple high-voltage 120 VAC input circuits and 10 A relay contact switching from the backplane logic bus. This internal architecture preserves high backplane bus communication velocity and logic scan execution during high-current relay switching operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC200UEX009-A expansion unit be mated to the main controller while powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Primary AC line power to both the CPU controller and the expansion unit must be de-energized prior to attaching or disconnecting expansion bus cables to protect logic circuitry from transient voltage damage.\u003c\/p\u003e\n\u003cp\u003eQ: What are the distinct load current limits for the integrated relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: The module provides two high-current relay output channels rated up to 10 A and four standard relay output channels rated up to 2 A.\u003c\/p\u003e\n\u003cp\u003eQ: What input power voltage range is required to operate this expansion unit?\u003c\/p\u003e\n\u003cp\u003eA: The unit features an integrated AC power supply capable of operating from a 120\/240 VAC supply line.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that all AC line power sources are completely de-energized prior to installation. Mount the IC200UEX009-A module on a standard 35 mm DIN rail or secure it to the sub-panel using mounting hardware. Connect the expansion bus cable firmly between the expansion interface ports of the CPU and expansion module. Connect 120\/240 VAC power to the main supply terminals and route 120 VAC input field cables separately from output load wiring. Ensure the protective earth terminal is grounded to a low-impedance cabinet chassis ground.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45414939394163,"sku":"IC200UEX009-A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC200UDR005-BA_1200x1200_081309ed-6fa4-4871-826c-5fd129a26656.jpg?v=1787902857","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic200uex009-a-expansion-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}