{"product_id":"ge-ic660bba106-i-o-block-module","title":"GE IC660BBA106 I\/O Block Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC660BBA106\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660BBA106\u003c\/strong\u003e Current Source Analog Input Block, operates as a dedicated hardware component for 0-20 mA and 4-20 mA current loop processing within GE Fanuc Genius I\/O network platforms. It directly interfaces up to 6 individually isolated analog transmitter channels to the serial bus without requiring a separate rack or external power supply module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660BBA106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.94 lbs (1.79 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.83 in x 3.56 in x 4.42 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W max heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Block Power\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Range\u003c\/td\u003e\n\u003ctd\u003e93-132 VAC \/ 105-145 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e6 current source inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e1 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of full reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Drift\u003c\/td\u003e\n\u003ctd\u003e70 ppm per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e16.6 ms to 400 ms (user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA Loop Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA106 provides 1500 V RMS channel-to-channel isolation across all 6 current source input circuits, shielding connected process instrumentation from high ground potential differences and transient noise. Operating with a 100 ohm input impedance and a resolution of 1 uA, the block continuously executes internal diagnostics for underrange, overrange, high alarm, low alarm, and open-wire conditions. Integrated circuit scaling and dual per-channel alarms allow raw process currents to be linearized and evaluated before diagnostic packets are transmitted across the Genius serial network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary power supply input requirements for operating the IC660BBA106?\u003c\/p\u003e\n\u003cp\u003eA: The block operates from a nominal source of 115 VAC (93-132 VAC range) or 125 VDC (105-145 VDC range), deriving both internal control power and loop excitation from this supply.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels on the IC660BBA106 be configured with custom update times?\u003c\/p\u003e\n\u003cp\u003eA: Yes, input conversion times are user-selectable on a per-block basis ranging from 16.6 ms to 400 ms, allowing customization between rapid response times and enhanced noise filtering (-45 dB at 50\/60 Hz).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect and lockout all incoming power sources (115 VAC \/ 125 VDC) and field signal lines prior to installing or servicing the block.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the unit to a vertical enclosure panel using standard mounting hardware to provide adequate heat dissipation and low-impedance frame grounding.\u003c\/li\u003e\n\u003cli\u003eWire signal loops using individual shielded twisted-pair cables for each 4-20 mA circuit. Ground signal shields strictly at one end to prevent ground loop noise from corrupting analog conversion.\u003c\/li\u003e\n\u003cli\u003eVerify that total loop resistance does not exceed the maximum allowable impedance limits (1000 ohms for 0-20 mA; 800 ohms for 20-25 mA).\u003c\/li\u003e\n\u003cli\u003eApply operating power and verify that both \"Unit OK\" and \"I\/O Enabled\" status LEDs illuminate steady ON, confirming successful self-test initialization and active communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":48385055948915,"sku":"IC660BBA106","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC660EBD1202_Cocoai_d7c5b200-bc27-424f-9242-831721fdd677.jpg?v=1789962648","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic660bba106-i-o-block-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}