{"product_id":"ge-ic660ebr100-relay-output-modules","title":"GE IC660EBR100 Relay Output Modules","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC660EBR100\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC660EBR100\u003c\/strong\u003e Relay Output Electronic Assembly utilized to execute discrete contact switching across Genius I\/O platforms. Designed to mount directly onto the IC660BBR100 terminal block base, the unit provides direct physical\/electrical execution to drive 16 normally closed (N.C.) relay output circuits over the serial Genius LAN network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660EBR100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Genius I\/O Block Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Genius Block Backplane Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Count\u003c\/td\u003e\n\u003ctd\u003e16 Output Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Form\u003c\/td\u003e\n\u003ctd\u003eNormally Closed (N.C.) Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eGenius LAN (155.6 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Base\u003c\/td\u003e\n\u003ctd\u003eIC660BBR100 Terminal Block Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDedicated Hardware Features\u003c\/h3\u003e\n\u003cp\u003eThe IC660EBR100 electronic assembly interfaces directly with the terminal base to execute localized contact switching while isolating backplane logic from load voltage spikes. Utilizing high-speed backplane bus communication velocity across the Genius network, the module processes discrete output commands with deterministic scan cycles. Onboard firmware flash compatibility allows synchronized CPU diagnostic reporting and hold-last-state operation during network signal loss.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC660EBR100 electronic assembly be replaced without loosening field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Yes, all physical field wiring connects directly to the passive IC660BBR100 terminal block base. The IC660EBR100 electronic assembly unlatches and can be swapped independently without disconnecting any field terminal screws.\u003c\/p\u003e\n\u003cp\u003eQ: What contact state do the outputs assume when power is lost to the IC660EBR100 module?\u003c\/p\u003e\n\u003cp\u003eA: Because the module features electromechanical Normally Closed (N.C.) relay contacts, the outputs revert to their unenergized closed state upon complete loss of control power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Disconnect all field load power sources and logic supply feeds prior to installing or removing the electronic assembly from the base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Mating:\u003c\/strong\u003e Align the rear connector frame of the IC660EBR100 with the matching receptacle on the IC660BBR100 terminal base, pressing firmly until the retention clips click into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the Genius LAN serial cable shield is connected directly to the shield terminal on the base to minimize high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Addressing:\u003c\/strong\u003e Program the assigned Genius LAN block address using a handheld monitor or setup software prior to putting the output loop into active service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45510501466227,"sku":"IC660EBR100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC660ELA100_Cocoai_b22c5060-b47a-458a-b446-8d0c51947804.jpg?v=1789634873","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic660ebr100-relay-output-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}