{"product_id":"ge-ic660ebs103-isolated-i-o-module","title":"GE IC660EBS103 Isolated I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC660EBS103\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660EBS103\u003c\/strong\u003e Isolated I\/O Electronic Assembly, operates as a dedicated hardware component for discrete signal processing and serial bus execution within Genius I\/O Block systems. Designed to mount directly onto the IC660BBS103 terminal block base, the unit provides direct physical\/electrical execution across eight individually isolated 115 VAC \/ 125 VDC circuits without failed switch diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660EBS103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Genius I\/O Block Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 125 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e8 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics Type\u003c\/td\u003e\n\u003ctd\u003eStandard (Without Failed Switch Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Base\u003c\/td\u003e\n\u003ctd\u003eIC660BBS103 Terminal Block Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eGenius LAN (155.6 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDedicated Hardware Features\u003c\/h3\u003e\n\u003cp\u003eThe IC660EBS103 electronic assembly interfaces through the terminal base to execute localized signal conditioning and channel-to-channel galvanic isolation. Leveraging high-speed backplane bus communication velocity across the Genius network, the unit processes discrete input\/output state changes with deterministic scan timing. Its onboard architecture features firmware flash compatibility for seamless integration with host controllers while isolating high-voltage field transients from the logic side.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC660EBS103 be removed from the terminal base without disconnecting field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Yes, all physical field wiring connects directly to the IC660BBS103 terminal block base. The IC660EBS103 electronic assembly can be unlatched and swapped independently without loosening any field wiring terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC660EBS103 module feature onboard failed switch diagnostic detection?\u003c\/p\u003e\n\u003cp\u003eA: No, the IC660EBS103 is designed specifically without failed switch diagnostics, making it suitable for standard isolated AC\/DC discrete circuits where continuous load monitoring is not required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure all 115 VAC \/ 125 VDC field power sources and logic power feeds are isolated before latching the electronic assembly onto the base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Mating:\u003c\/strong\u003e Align the connector pins on the rear of the IC660EBS103 with the receptacles on the IC660BBS103 terminal base, pressing down firmly until the side mechanical latches lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Termination:\u003c\/strong\u003e Connect the Genius LAN serial cable shield to the designated ground lug on the base assembly to ensure high-frequency transient suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Verification:\u003c\/strong\u003e Set the designated block serial address via the system hand-held monitor or configuration software prior to energizing the bus network.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45510494781555,"sku":"IC660EBS103","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC660ELA100_Cocoai_ae7a13c6-813f-4e35-998d-c0862874c7ed.jpg?v=1789634732","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic660ebs103-isolated-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}