{"product_id":"ge-ic660tbr100-terminal-blocks","title":"GE IC660TBR100 Terminal Blocks","description":"\u003cp\u003eConfigured for field wiring termination and mechanical interlock in GE Genius I\/O networks, the \u003cstrong\u003eGE IC660TBR100\u003c\/strong\u003e (\u003cstrong\u003eIC660TBR100\u003c\/strong\u003e Terminal Assembly) provides direct physical\/electrical execution. The terminal base accepts incoming field wiring signals and provides structural backplane interconnectivity for Genius electronic blocks (such as the IC660EBR100 and IC660BBR100 series). It acts as the permanent wiring interface, allowing electronic assemblies to be detached or replaced without disturbing physical field connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660TBR100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.30 lbs (0.59 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Genius I\/O terminal base footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive wiring interface (zero active power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGenius I\/O Block (Interfaces with IC660EBR100 \/ IC660BBR100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal barrier block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eTerminal Assembly Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC660TBR100 terminal assembly maintains backplane bus communication velocity across the internal Genius serial pass-through connections. Supporting clean I\/O density scaling in control enclosures, the rigid pin connector blocks eliminate impedance variations and maintain high signal integrity during high-speed data sampling. Full firmware flash compatibility is preserved across electronic assemblies mounted to the base, ensuring continuous transmission of diagnostic states to host CPUs without network latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can electronic assemblies mounted on the IC660TBR100 be serviced without disconnecting field wires?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the IC660TBR100 holds all physical field wiring screwed into its terminal blocks, permitting the attached electronic assembly to be unlatched and replaced independently.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC660TBR100 terminal assembly draw power from the backplane or field supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the unit is a passive wiring block containing internal bus bars and screw terminals with zero active electronic componentry or power consumption.\u003c\/p\u003e\n\u003cp\u003eQ: Which specific electronic assemblies pair with the IC660TBR100 terminal base?\u003c\/p\u003e\n\u003cp\u003eA: The IC660TBR100 is engineered to connect directly with the IC660EBR100 electronic assembly and form the foundation for IC660BBR100 Genius I\/O block configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the IC660TBR100 terminal assembly firmly to the panel or enclosure DIN rail prior to wiring.\u003c\/li\u003e\n\u003cli\u003eEnsure system control power and field circuit voltage sources are fully isolated before landing wires onto the screw terminals.\u003c\/li\u003e\n\u003cli\u003eWire field inputs, outputs, and power supplies strictly according to the terminal pinout diagram using properly sized ferrules.\u003c\/li\u003e\n\u003cli\u003eAlign the matching electronic assembly (e.g., IC660EBR100) with the IC660TBR100 base guides and press firmly until locked in place.\u003c\/li\u003e\n\u003cli\u003eConnect the terminal assembly ground lug to the cabinet protective earth (PE) bus to establish shield continuity for connected Genius serial communications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45498762788979,"sku":"IC660TBR100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC660TBD110_Cocoai.jpg?v=1789444994","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic660tbr100-terminal-blocks","provider":"DcsSupplier Limited","version":"1.0","type":"link"}