{"product_id":"ge-ic693alg223c-series-90-30-analog-current-input-module","title":"GE IC693ALG223C Series 90-30 Analog Current Input Module","description":"\u003cp\u003eThe GE \u003cstrong\u003eIC693ALG223C\u003c\/strong\u003e is a 16-channel analog current input module designed for the Series 90-30 PLC platform. It accepts 4-20 mA signals from field transmitters through single-ended inputs and converts them into digital values for PLC processing. Its 12-bit resolution, 13 ms update rate, and specified accuracy of +\/-0.25% of full scale at 25 deg C support process signal acquisition and monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Input Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC693ALG223C provides 16 single-ended analog current input channels, allowing multiple 4-20 mA field signals to be monitored through one PLC I\/O module. This high channel density helps consolidate transmitter connections within the Series 90-30 rack.\u003c\/p\u003e\n\u003cp\u003eThe 4-20 mA range is commonly used for industrial process instrumentation. The PLC can interpret the measured current as a process variable, such as pressure, temperature, flow, or level, according to the transmitter configuration and application scaling.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eResolution and Data Acquisition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses 12-bit conversion resolution, with a specified increment of 4 uA per count. This determines the digital granularity available for representing input current values. The stated update rate is 13 ms for all 16 channels, providing the specified data refresh interval for the complete input configuration.\u003c\/p\u003e\n\u003cp\u003eThe specified accuracy is +\/-0.25% of full scale at 25 deg C. This value describes the stated measurement accuracy under the specified temperature condition and should be distinguished from the 12-bit digital resolution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Wiring and Signal Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module receives its operating power through the PLC backplane, while the connected 4-20 mA field loops require an external power source for the field devices. The supplied information specifies a 24 VDC external supply for these loops. The field wiring arrangement should follow the manufacturer's terminal and grounding requirements.\u003c\/p\u003e\n\u003cp\u003eA current below the normal 4-20 mA operating range can indicate a broken wire or disconnected transmitter. The supplied description identifies a drop toward 0 mA as an under-range condition associated with a diagnostic fault bit in the PLC. The exact diagnostic threshold and fault-bit behavior should be verified against the applicable hardware manual.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE IC693ALG223C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Fanuc \/ Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Platform\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 Single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution Increment\u003c\/td\u003e\n\u003ctd\u003e4 uA per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e13 ms (all 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Power\u003c\/td\u003e\n\u003ctd\u003ePLC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Field Loop Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e138 x 25.4 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Condition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDcsSupplier Limited offers the GE IC693ALG223C as \u003cstrong\u003e100% brand new and in original factory condition\u003c\/strong\u003e, according to the supplied product information. Buyers should confirm the exact revision, packaging, and product identification when checking the delivered unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the GE IC693ALG223C require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module receives power through the PLC backplane. However, the connected field current loops require an external supply for the transmitters and associated field devices. The supplied information specifies 24 VDC for this purpose.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the IC693ALG223C detect a broken wire?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A broken loop can cause the measured current to fall toward 0 mA, below the normal 4-20 mA operating range. The supplied information describes this as an under-range condition that can trigger a PLC diagnostic fault bit. The exact detection threshold should be checked in the module documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IC693ALG223C accept 0-20 mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified input configuration is optimized for 4-20 mA signals. Although the supplied information mentions possible 0-20 mA use through PLC program scaling, the supported electrical input range and diagnostic behavior must be confirmed before using this configuration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":67226880344179,"sku":"IC693ALG223C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693ALG442B2_Cocoai_ad436c81-2d6c-4d5e-80d2-a5bcb19ac836.jpg?v=1794816155","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693alg223c-series-90-30-analog-current-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}