{"product_id":"ge-ic693chs392g-expansion-baseplates","title":"GE IC693CHS392G Expansion Baseplates","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CHS397G\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CHS392\u003c\/strong\u003e Expansion Baseplate, operates as a dedicated hardware component for local\/remote rack extension and discrete I\/O module interconnectivity within Series 90-30 PLC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CHS392G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e442 mm x 130 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e130 mA at 5 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Slots\u003c\/td\u003e\n\u003ctd\u003e10 slots (1 Power Supply slot, 9 I\/O slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot 1 Assignment\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots 2-10 Assignment\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O and Option Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC and +24 VDC backplane power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin D-type expansion connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe expansion baseplate integrates parallel backplane bus traces that maintain backplane bus communication velocity across all nine available expansion I\/O slots. High-speed logic buffer circuitry conditions incoming control frames from the master CPU rack via the 25-pin expansion port while retaining full firmware flash compatibility across all generations of Series 90-30 I\/O modules. Integrated trace termination minimizes signal reflections along the extended backplane communications lines during high-density I\/O polling cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can a CPU module be installed into Slot 1 of the IC693CHS392G baseplate?\u003c\/p\u003e\n\u003cp\u003eA: No. Slot 1 on the IC693CHS392G expansion baseplate is dedicated exclusively to the system power supply module. CPU modules must be installed in a primary CPU baseplate.\u003c\/p\u003e\n\u003cp\u003eQ: What cable connection is required to link the IC693CHS392G to the main CPU baseplate?\u003c\/p\u003e\n\u003cp\u003eA: The expansion baseplate connects to the CPU baseplate expansion bus using a standard Series 90-30 shielded expansion cable attached to the onboard 25-pin female D-type connector.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the baseplate securely to a flat, grounded enclosure panel using four M4 mounting screws through the corner slots.\u003c\/li\u003e\n\u003cli\u003eInstall the system power supply module into the leftmost position before populating any of the remaining nine I\/O slots.\u003c\/li\u003e\n\u003cli\u003eAttach the 25-pin D-type expansion cable between the preceding baseplate expansion port and the IC693CHS392G connector, tightening the retaining thumb screws.\u003c\/li\u003e\n\u003cli\u003eVerify that total expansion cable run length across all interconnected baseplates does not exceed the maximum system limit of 15 meters (50 feet).\u003c\/li\u003e\n\u003cli\u003eEnsure protective earth ground conductors are connected directly to the baseplate grounding stud to maintain electromagnetic interference suppression.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503490883699,"sku":"IC693CHS392G","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693CHS397K2_Cocoai_7473590f-e6ea-457b-aa71-cb7360149be4.jpg?v=1789537386","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693chs392g-expansion-baseplates","provider":"DcsSupplier Limited","version":"1.0","type":"link"}