{"product_id":"ge-ic693cpu374-kz-cpu-processors","title":"GE IC693CPU374-KZ CPU Processors","description":"\u003cp\u003eConfigured for high-speed logic execution and network data transmission in Series 90-30 PLCs, the \u003cstrong\u003eGE Fanuc IC693CPU374-KZ\u003c\/strong\u003e (\u003cstrong\u003eIC693CPU374\u003c\/strong\u003e CPU Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU374-KZ (IC693CPU374)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard GE Fanuc Factory Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard CPU Module Weight Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-Slot Baseplate Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Bus Draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e240 KB User Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Communications\u003c\/td\u003e\n\u003ctd\u003eEmbedded Ethernet Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSingle-Slot Baseplate Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe GE Fanuc IC693CPU374-KZ features built-in Ethernet connectivity, delivering rapid backplane bus communication velocity and deterministic network integration across factory networks.\u003c\/li\u003e\n\u003cli\u003eEmbedded TCP\/IP communications enable seamless remote monitoring, real-time data exchange, and direct Ethernet communication without requiring additional option cards.\u003c\/li\u003e\n\u003cli\u003eNative backplane architecture optimizes I\/O density scaling while maintaining full backward hardware compatibility for direct replacement of older Series 90-30 CPUs.\u003c\/li\u003e\n\u003cli\u003eIntegrated flash memory architecture guarantees firmware flash compatibility and secure program retention during power interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC693CPU374-KZ require an external Ethernet interface module to connect to factory networks?\u003c\/p\u003e\n\u003cp\u003eA: No, the module incorporates an onboard, embedded Ethernet interface directly on the CPU circuit board.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC693CPU374-KZ CPU module be hot-swapped while the baseplate is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, power to the Series 90-30 baseplate must be isolated before removing or installing the CPU module to prevent damage to backplane logic channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that incoming main power to the Series 90-30 baseplate is completely disconnected and tagged out before installing the module. Wear a grounded ESD wrist strap during handling to prevent static discharge to the internal microprocessor and memory components. Align the IC693CPU374-KZ module with slot 1 of the CPU baseplate and tilt it slightly backward to hook the top pivot notch onto the baseplate frame. Press the bottom of the module firmly into the baseplate until the rear connector seats completely and the module latch clicks into place. Connect the shielded Ethernet cable, ensuring the cable shield is grounded according to industrial noise suppression standards before applying system power.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PCTMG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e215.0 mm x 125.0 mm x 25.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eDrive Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003ePower Current Transformer (CT) Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransmitting AC current transducer feedback vectors across internal Mark V drive backplane structures, the board processes real-time phase current calculations to maintain fast-acting drive control loop responses.\u003c\/li\u003e\n\u003cli\u003eIntegrated onboard flash compatibility algorithms synchronize signal scaling parameters with primary processor logic, executing deterministic current monitoring without inducing data buffer delays or fieldbus interface latencies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the power CT monitor board interface with external current transducers inside the drive cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts secondary current outputs directly from field CT assemblies, conditioning low-level AC current signals before passing digitized feedback to the main drive control processor.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board hot-swappable during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is not permitted. Complete power shutdown and verified isolation of all high-voltage AC feeds are required before removing or installing the board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all AC and DC power sources supplying the drive cabinet, verifying zero energy state before accessing the card cage.\u003c\/li\u003e\n\u003cli\u003eUse a calibrated ESD grounding wrist strap attached to an unpainted metal surface on the drive frame during handling.\u003c\/li\u003e\n\u003cli\u003eAlign board edge connectors precisely with the rack backplane slots and slide the module smoothly until seated firmly.\u003c\/li\u003e\n\u003cli\u003eEnsure all current transformer secondary leads are securely landed at the terminal blocks and never left open-circuited while primary circuits are energized.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45320325857395,"sku":"IC693CPU374-KZ","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-06_16-06-45_1200x1200_83150671-11ef-430a-acac-e245b5f123d7.jpg?v=1786003971","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693cpu374-kz-cpu-processors","provider":"DcsSupplier Limited","version":"1.0","type":"link"}