{"product_id":"ge-ic693mdl940c-relay-output-module","title":"GE IC693MDL940C Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL940C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module, operates as a dedicated hardware component for high-power discrete load switching and interphase circuit isolation within Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 I\/O Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA at 5 VDC (backplane bus logic) \/ 135 mA at 24 VDC (relay coil execution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 Relay Outputs (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 125 VDC \/ 0 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A resistive per point \/ 4 A maximum per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC group-to-backplane; 500 VAC group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Platform\u003c\/td\u003e\n\u003ctd\u003eAutomate \/ Series 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL940C\u003c\/strong\u003e output module maintains deterministic backplane bus communication velocity across standard Series 90-30 sub-rack backplanes. Optical isolation barriers protect backplane signal traces from high-voltage field surges and switching transients, preserving backplane bus clock synchronization and firmware flash compatibility during high-density I\/O scan execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane power requirements for the IC693MDL940C?\u003c\/p\u003e\n\u003cp\u003eA: The IC693MDL940C requires 7 mA from the internal 5 VDC bus to power backplane logic and up to 135 mA from the 24 VDC relay supply when all output relay coils are energized.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 16 relay outputs isolated across field wiring points on the IC693MDL940C?\u003c\/p\u003e\n\u003cp\u003eA: The module configures 16 normally open outputs into two isolated groups of eight points each, providing 500 VAC group-to-group isolation and 1500 VAC isolation relative to the backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInsert the IC693MDL940C module into any standard I\/O slot of a Series 90-30 baseplate, pressing firmly until top and bottom latches click securely into the chassis backplane.\u003c\/li\u003e\n\u003cli\u003eTerminate load wiring at the 20-terminal removable connector, ensuring current per common return terminal does not exceed the maximum 4 A rating.\u003c\/li\u003e\n\u003cli\u003eInstall external RC surge suppressors across AC inductive loads or flyback diodes across DC inductive loads to mitigate contact arcing and extend relay contact lifespan.\u003c\/li\u003e\n\u003cli\u003eSeparate field output wiring from low-level communication or analog signal cables in panel wireways to prevent inductive noise coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":66815103729779,"sku":"IC693MDL940C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693CHS392C2_Cocoai_e12f1e6f-24b0-43cf-8315-27be54e44c1b.jpg?v=1791446677","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693mdl940c-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}