{"product_id":"ge-ic693mdl940f-relay-output-module","title":"GE IC693MDL940F Relay Output Module","description":"\u003cp\u003eConfigured for discrete load switching and physical contact isolation in Series 90-30 PLC platforms, the \u003cstrong\u003eGE Fanuc IC693MDL940F\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 40 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA at +5 VDC (backplane bus), 135 mA at +24 VDC Relay (backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points (4 isolated groups of 4 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC, 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per point, 4 A maximum per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS logic-to-field, 500 V RMS group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Series 90-30 backplane bus, utilizing optocoupler isolation to ensure stable communication velocity and system logic execution. Signal lines pass across high-speed optical barriers rated for 1500 V RMS to prevent field electrical noise from compromising internal CPU functions. The discrete outputs are structured into 4 independent isolated groups, optimizing I\/O density scaling while providing channel group galvanic separation to eliminate cross-talk during concurrent AC and DC switching cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC693MDL940F module include internal current protection fuses for field wiring circuits?\u003c\/p\u003e\n\u003cp\u003eA: No. The module does not contain internal fusing. External fuses must be installed on individual point lines or commons to protect internal relay contacts from overcurrent conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for the IC693MDL940F hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 7 mA from the internal +5 VDC backplane bus and 135 mA from the +24 VDC relay power bus during full load activation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main supply power to the PLC rack and field devices before inserting or removing the output module.\u003c\/li\u003e\n\u003cli\u003eAlign the module card with the designated baseplate slot and push firmly until the rear connector latches securely into the backplane.\u003c\/li\u003e\n\u003cli\u003eWire field output loads to the removable terminal block assembly, maintaining current limits within 2 A per point and 4 A per common terminal.\u003c\/li\u003e\n\u003cli\u003eRoute AC and DC field output cables in separate grounded metal conduits away from low-voltage DC logic and communication lines to prevent inductive noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503480725619,"sku":"IC693MDL940F","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL940F_Cocoai_a317ad00-ae1a-4477-b0d3-d9cf2232a6ef.jpg?v=1789529614","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693mdl940f-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}