{"product_id":"ge-ic693pwr330h-power-supply-module","title":"GE IC693PWR330H Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PWR330H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PWR330\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for system power conversion and backplane rail regulation within Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PWR330H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 40 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 VA max (AC) \/ 50 W max (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e30 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC or 100-300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 VDC Output Current\u003c\/td\u003e\n\u003ctd\u003eUp to 7 A (5.0-5.2 V, nominal 5.1 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 VDC Relay Output\u003c\/td\u003e\n\u003ctd\u003e24-28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated +24 VDC Output\u003c\/td\u003e\n\u003ctd\u003e21.5-28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Mechanisms\u003c\/td\u003e\n\u003ctd\u003eElectronic overcurrent protection, internal fuse, jumper-selectable overvoltage link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Connection\u003c\/td\u003e\n\u003ctd\u003e6-terminal removable block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated RS-485 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Power Architecture \u0026amp; Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe module is built with an integrated power conversion stage designed to maintain backplane bus communication velocity and stable rail regulation across expanded rack topologies. It delivers up to 7 A on the +5 VDC rail to ensure backplane logic integrity, while providing dedicated deterministic power feed paths for local CPU and expansion I\/O operations. Internal circuitry features electronic overcurrent limits and hardware jumper selection between terminals 3 and 4 for overvoltage loop suppression, maintaining signal purity and reducing noise coupling into high-density rack modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific slot location is required for mounting this power supply module on the baseplate?\u003c\/p\u003e\n\u003cp\u003eA: The module must always be installed in the leftmost slot (slot 0) of the Series 90-30 baseplate to properly interface with the backplane power bus.\u003c\/p\u003e\n\u003cp\u003eQ: How is overvoltage protection configured on the field wiring terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Overvoltage protection functionality is activated or bypassed via a hardware jumper connection placed across terminals 3 and 4 of the front 6-terminal block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the main line voltage source before attempting to mount or wire the power supply module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated leftmost slot of the baseplate until the rear backplane connectors and locking mechanisms fully engage.\u003c\/li\u003e\n\u003cli\u003eWire the incoming AC or DC supply lines to the 6-terminal block, ensuring protective conductor (earth ground) is properly bonded to terminal 1.\u003c\/li\u003e\n\u003cli\u003eMaintain proper field wiring isolation by routing input AC\/DC power cables separately from low-voltage signal wires and RS-485 serial communication cabling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503470141555,"sku":"IC693PWR330H","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDR390C_Cocoai_4f17b78d-ce51-418b-b391-a572e9372aae.jpg?v=1789525242","url":"https:\/\/www.dcssupplier.com\/products\/ge-ic693pwr330h-power-supply-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}