{"product_id":"ge-is200ectbg1ade-excitation-control-module","title":"GE IS200ECTBG1ADE Excitation Control Module","description":"\u003cp\u003eConfigured for excitation contact routing and emergency trip distribution within GE Excitation Control Systems, the \u003cstrong\u003eGeneral Electric IS200ECTBG1ADE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ECTBG1ADE\u003c\/strong\u003e Exciter Contact Terminal Board, operates as a dedicated hardware component for safety interlocking and discrete signal monitoring inside EX2100 Series platforms. This specific ECTBG1 variation is formatted exclusively for redundant control environments, interfacing directly with the master EMIO module to command system lockout drivers. It processes binary feedback loops, wet contact sensor inputs, and voting circuit matrices natively to protect the synchronous generator field excitation path.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ECTBG1ADE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2100 Excitation Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.10 kg (2.42 lbs baseline mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard EX2100 printed circuit board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via dual M1 and M2 controller distribution lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget System Integration\u003c\/td\u003e\n\u003ctd\u003eRedundant control setups only (ECTBG2 handles simplex layout)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Product Type\u003c\/td\u003e\n\u003ctd\u003eExciter Contact Terminal Board Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS200ECTBG1ADE handles safety-critical interlocking pathways, maintaining stable backplane bus communication velocity parameters across its local interface layer to ensure immediate actuation of trip relays. While the module communicates locally with the EMIO processor via proprietary high-speed ribbon links, the aggregate system tracks and distributes field status variables over industrial networks using Profinet or EtherNet\/IP deterministic networks via external communication gateways. The circuit design supports modular I\/O density scaling routines by organizing dedicated termination blocks for six auxiliary contact lines alongside the specialized 52G (generator circuit breaker) and 86G (lockout relay) contact points, preserving complete firmware flash compatibility with the host EX2100 core to prevent latency spikes during multi-point signal transitions.\u003c\/p\u003e\n\u003ch3\u003eContact Output and Wet Input Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Relay Architecture:\u003c\/strong\u003e Incorporates two dedicated trip outputs driven by the EMIO (Exciter Module Input\/Output) board, which command customer lockout mechanisms. The logic paths are formatted to actuate protective loops instantaneously upon detecting non-permissive field states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral-Purpose Form-C Outputs:\u003c\/strong\u003e Includes four general-purpose relay paths managed by the EMIO board. These Form-C outputs present physical Normally Open (NO), Normally Closed (NC), and Common (COM) terminal blocks, routing customer power loops for auxiliary system monitoring and feedback reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted Contact Inputs:\u003c\/strong\u003e Provides six customer-supplied auxiliary contact inputs powered and monitored by the ECTB framework using a 70 V DC nominal supply derived from plugs J13M1 and J13M2. This voltage is resistor-isolated, maintaining an active wetting voltage range of 63 to 84 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized Monitoring and Indications:\u003c\/strong\u003e The state of each contact input is tracked continuously, with the resulting status driving an onboard red indicating LED for local optical diagnostics. Signals are fanned out concurrently to controllers M1, M2, and C to secure complete multi-node redundancy, alongside dedicated tracking of the 52G and 86G inputs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45052981870707,"sku":"IS200ECTBG1ADE","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-28_10-41-54_41f031f1-612c-4baf-93e8-6c0da1641b1c.png?v=1779938727","url":"https:\/\/www.dcssupplier.com\/products\/ge-is200ectbg1ade-excitation-control-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}