{"product_id":"ge-is200trlyh1b-is200trlyh1bed-mark-vie-relay-output-board","title":"GE IS200TRLYH1B IS200TRLYH1BED Mark VIe Relay Output Board","description":"\u003cp\u003eConfigured for relay contact execution and solenoid actuation in General Electric Mark VIe control systems, the \u003cstrong\u003eGeneral Electric IS200TRLYH1BED\u003c\/strong\u003e (\u003cstrong\u003eIS200TRLYH1B\u003c\/strong\u003e Relay Output Board) provides direct physical\/electrical execution. The module accommodates up to 12 plug-in magnetic relays to route switching signals and solenoid power directly across industrial field control loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRLYH1BED (Base: IS200TRLYH1B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard terminal board weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm wide x 33.02 cm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 VDC, 115\/230 VAC standard; 24 VDC optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Channels\u003c\/td\u003e\n\u003ctd\u003e12 plug-in magnetic relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Flexibility\u003c\/td\u003e\n\u003ctd\u003eChannels 1 to 6 jumper-configurable (dry Form-C or external solenoid drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOnboard coil\/contact suppression, individual jumper-selectable fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYH1BED optimizes high-density output switching by isolating control logic from power-level field actuation. Channel-to-channel configuration jumpers allow circuits 1 through 6 to alternate between unpowered Form-C dry contacts and fused high-voltage drive outputs. High internal trace clearance combined with dedicated onboard arc suppression protects backplane communication paths against inductive voltage spikes during rapid relay cycling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are power supplies fused across the IS200TRLYH1BED board?\u003c\/p\u003e\n\u003cp\u003eA: Power input options (125 VDC, 115\/230 VAC, or optional 24 VDC) feature individual jumper-selectable fuses to isolate field supply lines.\u003c\/p\u003e\n\u003cp\u003eQ: Can the first six relay channels be modified for dry contact operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Relay channels 1 through 6 can be jumper-configured for either dry Form-C contact outputs or dedicated external solenoid drive lines.\u003c\/p\u003e\n\u003cp\u003eQ: What onboard surge mechanisms protect against coil inductive kickback?\u003c\/p\u003e\n\u003cp\u003eA: The board incorporates built-in voltage suppression circuitry directly parallel to the relay control lines to clamp transient electrical noise.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main field power and controller rack power are completely de-energized before mounting the board. Fasten the board onto the cabinet baseplate or DIN mounting hardware using standard mechanical hardware. Verify that jumper blocks for channels 1 through 6 are set strictly to match either dry-contact or solenoid voltage sourcing to prevent short circuits. Land field wiring onto terminal blocks with correct polarity, ensuring fuse selection jumpers align with the connected power source (125 VDC, 115\/230 VAC, or 24 VDC).\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45414913081459,"sku":"IS200TRLYH1B IS200TRLYH1BED","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/GEIS200TRLYH1BIS200TRLYH1BED_895f9102-7865-4ed1-aa6a-de0d784600f5.png?v=1787904182","url":"https:\/\/www.dcssupplier.com\/products\/ge-is200trlyh1b-is200trlyh1bed-mark-vie-relay-output-board","provider":"DcsSupplier Limited","version":"1.0","type":"link"}