{"product_id":"ge-is220pdioh1b-is230tndsh2a-discrete-i-o-pack","title":"GE IS220PDIOH1B（IS230TNDSH2A) Discrete I\/O Pack","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS220PDIOH1B\u003c\/strong\u003e (\u003cstrong\u003eIS230TNDSH2A\u003c\/strong\u003e) Discrete I\/O Pack operates as a high-speed signal processing component for the Speedtronic Mark VIe gas turbine control architecture. It handles discrete input acquisition and output actuation logic across simplex, dual, and triple-redundant system configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PDIOH1B (IS230TNDSH2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.26 cm x 4.19 cm x 12.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e28 V DC (Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e24 Inputs \/ 12 Outputs (Terminal Board Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The pack employs a standardized Mark VIe I\/O processor to execute input scanning and output command logic with a response time of less than 1 ms, ensuring deterministic behavior in critical turbine protection sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e Dual 10\/100 Mbps RJ-45 Ethernet ports support redundant communication paths over the SRTP-based Mark VIe I\/O network, maintaining continuous telemetry even during single-link failure events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The module supports mixed signal types, enabling the configuration of dry contact sensing and relay-driving outputs tailored to the specific TNDS terminal board interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The internal processor architecture allows for field-level firmware updates through the ControlST software suite, facilitating seamless integration with evolving turbine control logic and diagnostic requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS220PDIOH1B interchangeable with the IS230TNDSH2A?\u003c\/p\u003e\n\u003cp\u003eA: The IS220PDIOH1B is the discrete I\/O pack, while the IS230TNDSH2A is the compatible TNDS terminal board. They are not interchangeable; the pack must be mounted to the specified terminal board to complete the I\/O channel path.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module support redundant control configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware is designed for simplex, dual, and triple-redundant architectures. In redundant setups, the I\/O packs operate in parallel to ensure high-availability monitoring and control of the turbine system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the I\/O pack onto the designated carrier or TNDS terminal board. Ensure the electrical interface pins are properly aligned to prevent damage during insertion and to maintain reliable contact with the backplane circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure the pack to the system chassis ground. Robust grounding is required to ensure the efficacy of the galvanic isolation barriers and to protect the internal digital circuitry from transient surges and electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field devices to the TNDS terminal board using shielded cabling. Route discrete input and output wiring away from high-current power cables (minimum 150 mm separation) to prevent inductive crosstalk and maintain input signal threshold accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45212734849139,"sku":"IS220PDIOH1B（IS230TNDSH2A)","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-02_11-15-33.png?v=1783678034","url":"https:\/\/www.dcssupplier.com\/products\/ge-is220pdioh1b-is230tndsh2a-discrete-i-o-pack","provider":"DcsSupplier Limited","version":"1.0","type":"link"}