{"product_id":"ge-is220pturh1b-is230tntrh1c-primary-i-o-trip-pack-module","title":"GE IS220PTURH1B (IS230TNTRH1C) Primary I\/O Trip Pack Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS220PTURH1B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS220PTURH1B\u003c\/strong\u003e (IS230TNTRH1C) Primary I\/O Trip Pack Module, operates as a dedicated hardware component for turbine protection and control execution within Mark VI and Mark VIe Speedtronic control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS220PTURH1B \/ IS230TNTRH1C\u003c\/td\u003e\n\u003ctd\u003ePrimary Turbine I\/O Trip Pack Module (PTUR Rev B)\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI and Mark VIe Speedtronic Turbine Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS220PTUR...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eGE Mark VIe Protection and Control I\/O Packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PTURH1B (IS230TNTRH1C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.0 mm x 194.0 mm x 152.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27.4 to 28.6 VDC supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA (max load 900 Ohms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range \/ Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-3 Hz max slip \/ +\/-0.5% accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Driver Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS220PTURH1B trip pack incorporates dual 100 Mbps full-duplex Ethernet ports (ENET1 and ENET2) supporting high-speed signal acquisition across deterministic control loops. It interfaces directly with IS200TRPAS1A terminal boards to handle 8 flame detector inputs, 2 potential transformer inputs, and specialized speed measurement channels without processing latency. Furthermore, internal supervisory circuitry ensures robust electromagnetic immunity, firmware flash compatibility, and reliable synchronization across simplex and triple modular redundant (TMR) architectures under high I\/O density scaling demands.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply input range is required to operate the IS220PTURH1B I\/O pack?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an input voltage ranging from 27.4 to 28.6 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal board interfaces directly with this PTUR trip pack module?\u003c\/p\u003e\n\u003cp\u003eA: The module connects directly to IS200TRPAS1A terminal boards for signal conditioning and I\/O interfacing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all turbine control power distribution rails and field input feeds are completely de-energized, locked out, and tagged prior to mounting or wiring the IS220PTURH1B module. Mount the unit securely onto its plastic chassis utilizing the screw standoffs, ensuring proper physical separation from high-voltage noise sources. Terminate system connections firmly, verify the integrity of the dual Ethernet communication links, and check diagnostic LED states before restoring system power.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45289394503795,"sku":"IS220PTURH1B (IS230TNTRH1C)","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-02_11-15-33_61a74ad0-d8de-4130-9598-aa14ca1ca17b.png?v=1785312413","url":"https:\/\/www.dcssupplier.com\/products\/ge-is220pturh1b-is230tntrh1c-primary-i-o-trip-pack-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}