{"product_id":"ge-is220pturh1b-turbine-input-output-module","title":"GE IS220PTURH1B Turbine Input\/Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS220PTURH1B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS220PTUR\u003c\/strong\u003e Turbine Input\/Output Module, operates as a dedicated hardware component for primary turbine protection and emergency trip signal execution within Mark VIe control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS220PTUR\u003c\/td\u003e\n\u003ctd\u003ePrimary turbine protection I\/O pack base model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003eConformal coated board revision (Standard industrial version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eHardware revision level B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PTURH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg (1.12 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe I\/O pack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e28 VDC nominal (Backplane supply load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VIe Control Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eTurbine Input \/ Output \u0026amp; Emergency Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoated Board\u003c\/td\u003e\n\u003ctd\u003eConformal coated (H1 hardware revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Networks and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe I\/O pack communicates directly across dual-redundant EtherNet\/IP deterministic networks, ensuring low-latency packet transmission between turbine sensor interfaces and central controllers. Onboard flash memory maintains firmware flash compatibility with Mark VIe system releases, supporting remote configuration flashing without hardware physical removal. Microprocessor-driven onboard diagnostics continuously monitor internal power rails, analog-to-digital converter execution, and backplane bus communication velocity to ensure trip logic execution within millisecond timing limits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IS220PTURH1B communicate with the Mark VIe controller network?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes onboard dual RJ-45 Ethernet ports to interface with the IONet deterministic control network, transmitting high-speed digitized turbine protection inputs directly to central processing units.\u003c\/p\u003e\n\u003cp\u003eQ: Is online hot-swapping supported for the IS220PTURH1B I\/O pack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, online replacement is supported when the module is mounted on redundant terminal boards, provided standard electrostatic discharge (ESD) handling procedures are strictly observed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the associated terminal board power supply prior to seating or unseating the I\/O pack from its connector pins.\u003c\/li\u003e\n\u003cli\u003eAlign the mounting screws with the terminal board standoff posts and tighten securely to establish a firm chassis ground path.\u003c\/li\u003e\n\u003cli\u003eEnsure both Ethernet communications cables are clipped firmly into the IONet port connectors to maintain redundant communication paths.\u003c\/li\u003e\n\u003cli\u003eMaintain proper control enclosure ambient airflow to keep operating temperatures within the rated -30 to 65 deg C operating window.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45368482627699,"sku":"IS220PTURH1B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IS220PTURH1B_e2b8d900-1511-4256-b298-2bdc5d40ba07.png?v=1786949276","url":"https:\/\/www.dcssupplier.com\/products\/ge-is220pturh1b-turbine-input-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}