{"product_id":"ge-multilin-269plus-100p-120vac-269-plus-motor-management-relay","title":"GE Multilin 269PLUS-100P-120VAC 269 Plus Motor Management Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE Multilin 269PLUS-100P-120VAC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e269PLUS\u003c\/strong\u003e Motor Management Relay, operates as a dedicated hardware component for thermal overload protection and RTD temperature monitoring within motor control center platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e269PLUS-100P-120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.00 lbs (2.72 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 269 Plus Panel Cutout Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W (Maximum control load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Type\u003c\/td\u003e\n\u003ctd\u003e100 Ohm Platinum RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e4 Relay Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e269 Plus Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Communication Properties\u003c\/h3\u003e\n\u003cp\u003eAs an integrated protective relay component within industrial motor control architectures, the 269PLUS-100P-120VAC executes physical thermal modeling and signal conditioning:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks:\u003c\/strong\u003e Transmits motor operating parameters, thermal capacity usage, and fault diagnostic packets across industrial communication interface adapters to central supervisory control networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e Integrates four output relay contacts, 100 Ohm Platinum RTD temperature sensor inputs, and CT current sensing logic into a single front-panel module footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility:\u003c\/strong\u003e Onboard memory retains motor trip curves, pickup thresholds, and RTD temperature limits during complete control voltage power interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What control power sources are compatible with the 269PLUS-100P-120VAC relay?\u003c\/p\u003e\n\u003cp\u003eA: The relay accepts a nominal control voltage input of either 120 VAC or 125 VDC across its primary power supply terminals.\u003c\/p\u003e\n\u003cp\u003eQ: What RTD sensor configuration does this specific model variant support?\u003c\/p\u003e\n\u003cp\u003eA: This model variant is factory-configured to interface with 100 Ohm Platinum RTD temperature sensors for stator and bearing monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: How many physical output relay contacts are available on the terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The rear terminal interface provides 4 independent output relay connections for trip, alarm, and control interlock wiring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper mechanical cutout mounting and wiring practices maintain electrical isolation in motor control centers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout and Mechanical Mounting:\u003c\/strong\u003e Insert the relay housing through the prepared panel cutout from the front of the enclosure. Secure the unit firmly against the panel face using the provided mounting brackets and hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage and CT Wiring Isolation:\u003c\/strong\u003e Route control power leads and current transformer (CT) secondary wiring through separate wire conduits. Ensure CT circuits are securely landed before energizing the main power circuit to prevent high open-circuit voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding for RTD Inputs:\u003c\/strong\u003e Connect all 100 Ohm Platinum RTD shielded wiring directly to the designated relay shield terminal. Terminate cable shields at a single ground point to prevent ground loops from degrading analog temperature measurements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45303673978995,"sku":"269PLUS-100P-120VAC","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-11_17-20-06_9e794199-1c3e-4892-aad8-42b5c4adb5b2.png?v=1785833647","url":"https:\/\/www.dcssupplier.com\/products\/ge-multilin-269plus-100p-120vac-269-plus-motor-management-relay","provider":"DcsSupplier Limited","version":"1.0","type":"link"}