{"product_id":"ge-qpi-2d101-s2p-quickpanel-hmi-module","title":"GE QPI-2D101-S2P QuickPanel HMI Module","description":"\u003cp\u003eConfigured for real-time visual process monitoring and operator data execution in industrial network platforms, the \u003cstrong\u003eGE QPI-2D101-S2P\u003c\/strong\u003e (\u003cstrong\u003eQPI-2D101-S2P\u003c\/strong\u003e HMI Module) provides direct physical\/electrical execution. The hardware integrates a 10.4 inch STN color display powered by a nominal 24 VDC input voltage. Designed with serial communication ports and an analog resistive touch surface, it interfaces directly with programmable logic controllers to output system parameters, alarm states, and machine diagnostics in real time without operational delay.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI-2D101-S2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e10.4 inch STN Color LCD (8 Solid \/ 8 Flashing Colors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 Pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Panel Technology\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive (32 x 24 Matrix Resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e317 mm x 243 mm x 77 mm (12.48 in x 9.57 in x 3.05 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65 Front Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural Air Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface Ports\u003c\/td\u003e\n\u003ctd\u003e2 x Serial I\/O Ports, 1 x Dedicated Download Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 deg C (32 to 104 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7 or Higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe unit features native serial protocol drivers and deterministic network communication handling to maintain tight synchronization with PLC backplane bus execution cycles. Firmware flash memory integrated into the motherboard allows direct update verification and non-volatile project memory retention during power cycles. Built-in serial channel isolation prevents ground loop interference across long signal runs, ensuring seamless bandwidth integrity across industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the required input voltage tolerance for the GE QPI-2D101-S2P during full load operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit operates on a nominal 24 VDC power supply. Safe operational tolerances require a stabilized voltage within 20.4 VDC to 28.8 VDC to prevent thermal overload on internal power conversion circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How does the front bezel seal maintain its NEMA Type 4X\/12 and IP65 ratings during panel mounting?\u003c\/p\u003e\n\u003cp\u003eA: Protection compliance relies on a continuous synthetic rubber gasket compressed uniformly around the panel cutout. Mount clips must be torqued evenly to maintain water-tight and oil-tight sealing integrity against atmospheric contaminants.\u003c\/p\u003e\n\u003cp\u003eQ: Can the serial interface ports handle simultaneous communication and project file downloads?\u003c\/p\u003e\n\u003cp\u003eA: The module contains two independent serial I\/O communication ports alongside a dedicated download port, enabling runtime PLC data logging concurrently with runtime application uploads\/downloads without disconnecting active field buses.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the enclosure mounting cutout conforms to the exact panel dimensions. Secure the unit using all provided mounting fasteners, tightening them in an alternating diagonal pattern to achieve uniform pressure on the perimeter sealing gasket. Connect the chassis ground terminal directly to a dedicated low-impedance earth ground bus using stranded copper conductor (minimum 14 AWG) to eliminate electrostatic discharge risks.\u003c\/p\u003e\n\u003cp\u003eRouting of power conductors (24 VDC) and serial communication cabling must maintain a minimum clear distance of 100 mm from high-voltage AC lines and variable frequency drive outputs to prevent inductive cross-talk. Confirm natural air convection pathways remain unobstructed by providing at least 50 mm of vertical air clearance above and below the rear enclosure housing.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45410546909299,"sku":"QPI-2D101-S2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPI-3D200-E2P_2_90324e94-52a4-40c3-bf03-c376e25e1a1e.png?v=1787796448","url":"https:\/\/www.dcssupplier.com\/products\/ge-qpi-2d101-s2p-quickpanel-hmi-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}