{"product_id":"ge-qpi21100c2p-quickpanel-operator-interface","title":"GE QPI21100C2P QuickPanel Operator Interface","description":"\u003cp\u003eConfigured for real-time visualization and tactile operator control in industrial control platforms, the \u003cstrong\u003eGE QPI21100C2P\u003c\/strong\u003e (\u003cstrong\u003eQPI21100C2P\u003c\/strong\u003e Operator Interface Display) provides direct physical\/electrical execution. The hardware processes operator inputs via its integrated front interface panel while converting backplane signal traffic into graphical plant diagnostics. Engineered for control cabinet cutouts, it establishes local human-machine interactions across legacy PLC networks, ensuring continuous visual monitoring of machine states and system alarms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI21100C2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ QuickPanel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.99 lbs (4.08 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 10.5 in Display Panel Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eTFT Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Size\u003c\/td\u003e\n\u003ctd\u003e10.5 in diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (Front Panel Seal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Determinism\u003c\/h3\u003e\n\u003cp\u003eThe unit relies on high-speed backplane bus communication velocity and firmware flash compatibility to execute real-time polling of controller registers. Channel processing latencies are minimized through direct parallel memory mapping, preventing visual frame tearing during rapid parameter changes. The internal communication processor manages deterministic serial or fieldbus updates, maintaining link stability despite electro-magnetic interference (EMI) standard in high-voltage switching environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary power connection requirements apply to the hardware panel?\u003c\/p\u003e\n\u003cp\u003eA: The unit requires a dedicated single-phase AC source supplying 100-120 VAC at 50\/60 Hz. Power wiring must be verified for correct line, neutral, and protective earth terminations before energizing.\u003c\/p\u003e\n\u003cp\u003eQ: How is the IP65 front panel rating maintained during enclosure installation?\u003c\/p\u003e\n\u003cp\u003eA: IP65 integrity depends on a continuous, uncompressed perimeter gasket sealed against a smooth, rigid cabinet cutout. All rear mounting clamps must be torqued evenly to prevent frame distortion.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit support hot-swapping while live AC power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No. AC supply power and communication connectors must be de-energized prior to removing or replacing the unit to prevent electrical arcing and memory corruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePrior to cabinet integration, verify panel cutout dimensions match the hardware frame constraints. Seat the sealing gasket uniformly along the front bezel channel without twisting. Insert the unit through the front panel cutout and secure it using all supplied mounting clips. Tighten clips in an alternating cross pattern to ensure equal gasket compression against the enclosure surface.\u003c\/p\u003e\n\u003cp\u003eConnect protective earth (PE) grounding directly to the designated chassis terminal using a low-impedance copper conductor. Route power input lines (100-120 VAC) in conduit separate from low-voltage communication cables to mitigate inductive cross-talk. Ground cable shields at one end only as specified by network topology guidelines. Maintain a minimum 50 mm clearance around rear heat sinks to allow unhindered convective cooling airflow.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45410549956723,"sku":"QPI21100C2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPI-3D200-E2P_3_a7851d17-4cc6-4227-893c-b8cb9df7f598.png?v=1787796695","url":"https:\/\/www.dcssupplier.com\/products\/ge-qpi21100c2p-quickpanel-operator-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}