{"product_id":"ge-qpi21100s2p-operator-interface-module","title":"GE QPI21100S2P Operator Interface Module","description":"\u003cp\u003eConfigured for real-time visualization and localized machine control execution in industrial control network architectures, the \u003cstrong\u003eGE Fanuc QPI21100S2P\u003c\/strong\u003e (\u003cstrong\u003eQPI21100\u003c\/strong\u003e Operator Interface Terminal) provides direct physical\/electrical execution. It handles human-machine interaction by rendering system telemetry and accepting operator inputs over serialized backplane bus pathways. Operating on an input voltage rating of 120 VAC, this panel replaces hardwired control elements, delivering visual feedback via a 10.4-inch Super Twisted Nematic (STN) color LCD panel with a resolution of 640 x 480 pixels built for industrial environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI21100S2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Total Control Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.6 lbs (3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.48 in x 9.57 in x 3.05 in (317 mm x 243 mm x 77 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 45 deg C (32 to 113 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eSTN Color LCD (8 solid mode \/ 8 flashing mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Size\u003c\/td\u003e\n\u003ctd\u003e10.4 inches (Display area 8.48 in W x 6.32 in H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT (Operator Interface Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe unit relies on high-speed backplane bus communication velocity and deterministic serial polling protocols to synchronize digital state tables with host programmable logic controllers. Firmware flash compatibility checks ensure seamless bitmask alignment across serial communication drivers during software project loading via QuickDesigner. The high-density I\/O mapping profile transfers digital registers without introducing scanning delays, enabling rapid state updating across connected PLC networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What display characteristics define full color on the STN LCD module?\u003c\/p\u003e\n\u003cp\u003eA: The Super Twisted Nematic (STN) LCD renders visual graphics using a matrix capability of 8 solid colors and 8 flashing colors.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit require isolated power wiring for its AC input source?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The panel operates on 120 VAC power, which must be routed through separate conduits away from sensitive low-voltage DC signals and serial communication cables to prevent electromagnetic noise coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module into a enclosure cutout matching the 317 mm x 243 mm outer dimensions. Ensure the NEMA Type 4X\/12 and IP65 perimeter sealing gasket is compressed evenly around the front bezel frame to maintain ingress protection. Connect a dedicated low-impedance protective earth (PE) ground wire directly to the chassis grounding terminal on the panel assembly. Route all serial communication lines separately from the 120 VAC main power source to protect communication circuitry from electrical noise.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45410549858419,"sku":"QPI21100S2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPI-3D200-E2P_2_148753fa-af29-433b-b38a-965ed1c336e2.png?v=1787796406","url":"https:\/\/www.dcssupplier.com\/products\/ge-qpi21100s2p-operator-interface-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}