{"product_id":"ge-qpi2d100e2p-human-machine-interfaces","title":"GE QPI2D100E2P Human Machine Interfaces","description":"\u003cp\u003eThe \u003cstrong\u003eGE QPI2D100E2P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eQPI2D100E2P\u003c\/strong\u003e Operator Interface, operates as a dedicated hardware component for monochrome graphical visualization and operator input within GE Fanuc QuickPanel industrial network platforms. The unit features an 8.9 inch high-intensity electroluminescent (EL) display powered by an external 24 VDC power supply to display real-time machine parameters, diagnostic alerts, and process status updates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI2D100E2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e8.9 inch Monochrome High-Intensity EL Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT Operator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.11 kg (4.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 8.9 in Panel Mount Enclosure Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65 (Front Bezel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 45 deg C (32 to 113 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe hardware includes specialized circuitry designed to optimize backplane bus communication velocity across legacy PLC architectures. Integrated firmware flash memory ensures non-volatile retention of runtime operator interface screens and configuration settings during complete site power loss. Built-in serial driver management provides deterministic network response during continuous data exchanges between the high-intensity EL panel and remote industrial controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary installation power requirements for the GE QPI2D100E2P?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a regulated 24 VDC external power source. Wiring must maintain proper polarity and low-impedance grounding to isolate the display electronics from industrial power line fluctuations.\u003c\/p\u003e\n\u003cp\u003eQ: How does the electroluminescent display handle low-light and harsh operating conditions?\u003c\/p\u003e\n\u003cp\u003eA: The high-intensity monochrome EL display emits direct light without requiring a separate backlight CCFL tube, ensuring stable text contrast and fast display response across wide industrial temperature ranges.\u003c\/p\u003e\n\u003cp\u003eQ: Is the firmware flash memory field-upgradable during system maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Yes, onboard flash memory permits application downloads and firmware updates directly via the download port without requiring physical removal of memory chips from the main processing board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit directly into a clean, flat control panel cutout using the provided mounting hardware. Tighten fasteners evenly around the perimeter to achieve positive compression on the front bezel seal, ensuring protection against environmental dust and splashing liquids. Connect the panel ground terminal to a local protective earth point using heavy-gauge copper wiring (14 AWG minimum) to eliminate electrostatic discharge risks.\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum distance of 100 mm between communication lines, 24 VDC power cables, and high-voltage AC conductors or variable speed drive wiring to suppress electromagnetic interference. Verify that ambient air flow around the rear enclosure remains unobstructed to allow effective natural heat dissipation during continuous operation.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45410549137523,"sku":"QPI2D100E2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPL2D200C2P_824a408f-2c3a-441b-96fe-91efe02d2f2f.png?v=1787796422","url":"https:\/\/www.dcssupplier.com\/products\/ge-qpi2d100e2p-human-machine-interfaces","provider":"DcsSupplier Limited","version":"1.0","type":"link"}