{"product_id":"ge-qpj-2d100-l2p-quickpanel-jr-hmi-module","title":"GE QPJ-2D100-L2P QuickPanel Jr. HMI Module","description":"\u003cp\u003eConfigured for real-time operator interaction and visual monitoring in GE PLC networks, the \u003cstrong\u003eGE QPJ-2D100-L2P\u003c\/strong\u003e (\u003cstrong\u003eQPJ2D100S2P\u003c\/strong\u003e HMI Module) provides direct physical\/electrical execution. The unit processes field signal states into 16-hue visual displays and translates physical screen inputs into logic execution commands across local controller backplane connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPJ-2D100-L2P (QPJ2D100S2P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg (1.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171.5 x 127.0 x 54.0 mm (6.75 x 5.00 x 2.125 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 45 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (20.4 to 27.6 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e4.7-inch STN Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e240 x 320 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12 (IP65 front bezel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Deterministic Networking\u003c\/h3\u003e\n\u003cp\u003eThe unit utilizes dedicated memory architecture to optimize display processing and maintain firmware flash compatibility across legacy GE system configurations. Integrated serial communication controllers manage protocol conversion latencies, sustaining deterministic data exchange with PLC CPUs. The power supply stage incorporates a 20 ms immunity window against line voltage sags, isolating sensitive internal logic circuits from field supply transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What insulation and voltage withstand thresholds apply to the power interface of the QPJ-2D100-L2P?\u003c\/p\u003e\n\u003cp\u003eA: The electrical power circuit maintains an insulation resistance of 10 Mohm at 500 VDC and withstands continuous isolation testing up to 1500 VAC.\u003c\/p\u003e\n\u003cp\u003eQ: How is thermal management handled within sealed industrial enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on natural convection cooling through internal heatsink channels. Operational ambient temperatures must remain within 0 to 45 deg C without requiring secondary forced-air cooling fans.\u003c\/p\u003e\n\u003cp\u003eQ: What voltage tolerance does the internal power converter accept?\u003c\/p\u003e\n\u003cp\u003eA: While nominal supply voltage is 24 VDC, the internal power regulator accepts continuous operational inputs from 20.4 VDC to 27.6 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCut panel mounting opening according to standard cutout dimensions and verify the sealing gasket is correctly seated around the front bezel.\u003c\/li\u003e\n\u003cli\u003eInsert the unit from the front of the enclosure door and tighten all rear mounting clamps evenly to preserve NEMA 4X\/12 (IP65) ingress protection.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC power conductors using heavy-gauge wire, observing strict polarity markings on the terminal block.\u003c\/li\u003e\n\u003cli\u003eBond the protective earth ground terminal directly to the enclosure frame backplate using a low-impedance copper strap to prevent electrostatic discharge.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45401292013683,"sku":"QPJ-2D100-L2P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPK-3D200-L2P_0873336a-5004-4083-b679-dada6360c9e7.png?v=1787727565","url":"https:\/\/www.dcssupplier.com\/products\/ge-qpj-2d100-l2p-quickpanel-jr-hmi-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}