{"product_id":"ge-ur5ch-transducer-i-o-module","title":"GE UR5CH Transducer I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE UR 5CH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR 5CH\u003c\/strong\u003e Transducer I\/O Module, operates as a dedicated hardware component for temperature and RTD sensor signal acquisition within Universal Relay (UR) platforms. The horizontal rack-mountable module conditions and digitizes analog inputs from up to 8 field RTD sensors, transmitting process data across the backplane to the primary protection and control processor without introduce measurement offset or thermal drift.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 5CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.92 kg (2.03 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20.3 cm x 15.2 cm x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e8 RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal unit \/ rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module communicates over the high-speed Universal Relay backplane bus, utilizing deterministic protocols to transfer digitized multi-channel RTD readings directly to the main CPU module. Designed for scalable I\/O density within standard UR chassis configurations, the module manages analog-to-digital sampling across all 8 channels simultaneously. Internal firmware ensures synchronization with system time tags and maintains protocol integrity during continuous multi-channel backplane polling cycle execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module maintain reading accuracy across the 8 RTD channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel incorporates internal precision reference circuitry to compensate for ambient temperature variations and lead wire resistance, ensuring uniform signal conditioning prior to analog-to-digital conversion.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be inserted or removed while the UR chassis is fully powered?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement should be performed with control power removed from the UR rack or in strict accordance with GE Universal Relay chassis maintenance procedures to prevent backplane bus communication interruptions or transient alarms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the module into the designated horizontal slot of the Universal Relay chassis until the backplane multi-pin connectors fully engage.\u003c\/li\u003e\n\u003cli\u003eSecure the module retaining screws on the front panel to establish chassis ground continuity and prevent vibration-induced displacement.\u003c\/li\u003e\n\u003cli\u003eRoute RTD sensor lead wires through shielded twisted-pair cables, keeping signal wiring separated from high-voltage AC current transformer (CT) or potential transformer (PT) wiring.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to the designated panel ground bus at a single point to prevent ground loops from degrading 8-channel RTD measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45371254669427,"sku":"UR5CH","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/UR5CH_1200x1200_0bbf45db-e462-4652-8636-41a78ed9b669.jpg?v=1787043646","url":"https:\/\/www.dcssupplier.com\/products\/ge-ur5ch-transducer-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}