{"product_id":"ge-ur7cm-multilin-communication-module","title":"GE UR7CM Multilin Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc UR7CM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMultilin Communication Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay (UR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module serves as the primary data gateway, allowing the relay to interface with SCADA systems, HMIs, and other substation IEDs. Supporting a wide array of industry-standard protocols—including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850, DNP3, and Modbus RTU\u003c\/strong\u003e—the UR7CM ensures seamless data exchange and system interoperability. \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc \/ General Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultilin Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 61850, DNP3, Modbus RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2x High-speed Ethernet ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1x RS-232 and 1x RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e180 mm (L) x 100 mm (W) x 50 mm (H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features and Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSimultaneously manages various protocols like IEC 61850 for substation automation and DNP3 or Modbus for SCADA reporting, reducing the need for external protocol converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual Ethernet ports allow for redundant network topologies, ensuring that the relay remains visible to the control center even if one communication path is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes both RS-232 and RS-485 ports to support legacy field devices and local configuration tools alongside modern networked infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for operation from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C up to +70°C\u003c\/strong\u003e, the UR7CM is built to perform in the most demanding climates and unconditioned substation cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Data Exchange:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized to work with the Multilin backplane, ensuring that time-stamped events and protection data are transmitted with high precision and minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Modular Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s 100mm width allows for easy integration into standard UR chassis slots, facilitating rapid communication upgrades for existing B30, C60, or T60 relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44940755501171,"sku":"UR7CM","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-09_10-11-30_41c51940-2fd2-4cc0-be32-c5928aac3c0a.png?v=1778294441","url":"https:\/\/www.dcssupplier.com\/products\/ge-ur7cm-multilin-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}