{"product_id":"general-electric-ds200pccag9a-power-connect-card","title":"General Electric DS200PCCAG9A Power Connect Card","description":"\u003cp\u003eConfigured for power conversion execution in EX2000 excitation control system networks, the \u003cstrong\u003eGeneral Electric DS200PCCAG9A\u003c\/strong\u003e (\u003cstrong\u003eDS200PCCAG9A\u003c\/strong\u003e Power Connect Card) provides direct physical\/electrical execution via internal gate pulse transformers and snubber circuit interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PCCAG9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard printed circuit board assembly form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.9 cm high x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 V DC, 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e28 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Channels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Manual\u003c\/td\u003e\n\u003ctd\u003eGEH-6005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates surface-mount electronic component layouts designed to process high-speed gating signals across industrial excitation platforms. Backplane bus communication velocity and firmware flash compatibility are maintained through rigorous signal conditioning pathways, ensuring precise phase control and synchronous firing pulses to the SCR power bridge. Gate pulse amplifiers convert gate array outputs into the necessary power levels for forward and reverse gate pulse transformers, while interlock mechanisms suppress firing power until internal logic stabilization and +5 V rail regulation are fully validated.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical power requirements for operating the DS200PCCAG9A card? A: The board requires a +5 V DC power input at 6 A along with a 28 V DC power supply voltage.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module interface with the SCR power bridge?\u003c\/p\u003e\n\u003cp\u003eA: It utilizes internal gate pulse transformers driven by gate pulse amplifiers to deliver controlled firing signals.\u003c\/p\u003e\n\u003cp\u003eQ: What role do snubber circuits play on the Power Connect Card? A: They control and suppress voltage spikes across the AC lines, DC bus, and gate drivers in low-to-medium horsepower controllers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the excitation control system is completely de-energized, locked out, and fully discharged of hazardous voltages prior to handling internal components.\u003c\/li\u003e\n\u003cli\u003eObserve standard electrostatic discharge (ESD) precautions by wearing a grounded wrist strap while handling the surface-mount printed circuit board.\u003c\/li\u003e\n\u003cli\u003eAlign the Power Connect Card carefully into the designated EX2000 rack slot, ensuring secure pin engagement with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eVerify system voltage, frame size, and power conversion configuration (regenerative versus non-regenerative) match the designated group number requirements.\u003c\/li\u003e\n\u003cli\u003eRestore control power, verify that the +5 V rail regulation and gate array initialization complete successfully, and monitor operational status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45295989227635,"sku":"DS200PCCAG9A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/DS200PCCAG9A.jpg?v=1785485380","url":"https:\/\/www.dcssupplier.com\/products\/general-electric-ds200pccag9a-power-connect-card","provider":"DcsSupplier Limited","version":"1.0","type":"link"}