{"product_id":"hima-m3410-safety-relay-module","title":"HIMA M3410 Safety Relay Module","description":"\u003cp\u003eConfigured for safety-related process automation execution in HIMA programmable electronic environments, the \u003cstrong\u003eHIMA M3410\u003c\/strong\u003e (\u003cstrong\u003eM3410\u003c\/strong\u003e Safety Relay Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eM3410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 mm x 144 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3, PLe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Integrity \u0026amp; Fail-Safe Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL 3 and PLe Certification:\u003c\/strong\u003e The diagnostic coverage and structural redundancy of the internal logic circuits are certified to satisfy IEC 61508 SIL 3 and EN ISO 13849-1 Performance Level e (PLe) safety metrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe State Execution:\u003c\/strong\u003e Upon detection of an open-circuit, short-circuit, or internal cross-fault via self-diagnosis, the module forces the 4 relay outputs to a de-energized fail-safe open state within the 10 ms response time window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Internal evaluation logic maintains strict electrical isolation from the 24 VDC digital input channels and relay contacts to inhibit common-mode voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple Modular Redundancy (TMR) Compatibility:\u003c\/strong\u003e The module structures loop monitoring feedback parameters to enable continuous system-level verification across redundant safety architecture configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific hardware monitoring loops are processed by the internal diagnostic functions?\u003c\/p\u003e\n\u003cp\u003eA: The internal hardware diagnostics execute continuous cross-channel comparisons alongside active pulse testing on the 8 digital inputs to detect line short-circuits, cross-talk, and field wiring open-circuit faults instantly.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 4 relay outputs be split into independently controlled safety circuits?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 4 relay outputs are electrically separated, allowing different safety interlock or emergency shutdown circuits to be wired across the termination blocks while adhering to the 10 ms response execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the primary 24 VDC power supply is completely isolated and de-energized prior to inserting, removing, or wiring the module terminals. Mount the 72 mm x 144 mm x 100 mm housing securely onto standard industrial DIN rail assemblies within a protective cabinet to prevent environmental contamination. Maintain a physical separation gap of at least 50 mm from adjacent inductive heat sources to prevent thermal degradation of the internal mechanical relays. All safety switch and sensor wiring attached to the 8 digital inputs must use shielded twisted-pair cables, with the shield terminated exclusively at the control cabinet ground bar.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45235411681395,"sku":"M3410","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-13_10-06-27_cbb17bc5-0052-4b77-894d-3786d01a9704.png?v=1784022721","url":"https:\/\/www.dcssupplier.com\/products\/hima-m3410-safety-relay-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}