{"product_id":"honeywel-fc-iochas-0001r-safety-manager-redundant-i-o-chassis","title":"Honeywel FC-IOCHAS 0001R Safety Manager Redundant I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-IOCHAS-0001R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Redundant I\/O Module Chassis engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocess safety platform. Designed as a core component for safety-critical hardware deployments, this robust rack provides the physical structural framework, internal backplane bus wiring, and power distribution tracks needed to mount paired, redundant input\/output cards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell Process Solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-IOCHAS-0001R\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family Integration\u003c\/strong\u003e: Honeywell Safety Manager \/ Safety Manager SC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Classification\u003c\/strong\u003e: Redundant I\/O Subrack Chassis Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArchitecture Configuration\u003c\/strong\u003e: Dual-channel parallel path backplane optimization for paired safety modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Alignment Focus\u003c\/strong\u003e: Multi-slot layout equipped with precise vertical card guides and high-retention bus sockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e: Fully supports active online hot-swapping of modules without dropping safety loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution Infrastructure\u003c\/strong\u003e: Integrated heavy-duty power bus plane for stable 24VDC system rail sharing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Grounding\u003c\/strong\u003e: Dedicated low-impedance chassis and signal grounding grounding terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Installation Envelope\u003c\/strong\u003e: 19-inch standard rack-mountable ears integrated into the front chassis face\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Gross Shipping Mass\u003c\/strong\u003e: 3.0 kg (6.61 lbs) sturdy protective container layout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Condition Profile\u003c\/strong\u003e: Brand New \u0026amp; Original in Factory Packing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Coverage\u003c\/strong\u003e: 12 Months Factory Warranty included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Safety I\/O Expansion\u003c\/strong\u003e: Provides the physical backplane framework to slot side-by-side redundant digital input, digital output, or analog input cards within emergency shutdown panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Shutdown (ESD) Systems\u003c\/strong\u003e: Deploys inside central processing safety racks for offshore platforms, keeping valve monitoring active even if one I\/O card encounters a fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Burner Control Housing\u003c\/strong\u003e: Holds critical flame monitoring and fuel isolation I\/O channels in high-reliability burner management system cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eToxic Gas Redundant Marshalling\u003c\/strong\u003e: Collects safety signals from multiple gas detection cards across refinery sectors, routing them through a dual-bus backplane for maximum uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45024299843699,"sku":"FC-IOCHAS 0001R","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-21_17-41-18_61297222-2232-49ed-b73e-d5bb5f88a228.png?v=1779357077","url":"https:\/\/www.dcssupplier.com\/products\/honeywel-fc-iochas-0001r-safety-manager-redundant-i-o-chassis","provider":"DcsSupplier Limited","version":"1.0","type":"link"}