{"product_id":"honeywel-fc-sdo-o824-safety-manager-digital-output-module","title":"Honeywel FC-SDO-O824 Safety Manager Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"text-block-with-attachment\"\u003e\u003cspan class=\"attachment-container search-images\"\u003e\u003c\/span\u003e\u003cspan\u003eThe Honeywell \u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e is a high-integrity, fail-safe Digital Output Module engineered for the \u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e process safety platform. Acting as a critical interface within Safety Instrumented Systems (SIS), this module provides 8 independent, heavily monitored output channels designed to safely actuate field-mounted equipment. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell Process Solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Hardware Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family Integration\u003c\/strong\u003e: Honeywell Safety Manager \/ Safety Manager SC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Classification\u003c\/strong\u003e: Safe Digital Output (SDO) Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Signal Channels\u003c\/strong\u003e: 8 independent fail-safe outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Loop Output Voltage\u003c\/strong\u003e: 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Continuous Channel Current\u003c\/strong\u003e: 550 mA per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Safety Line Diagnostics\u003c\/strong\u003e: Automated checking for open-circuit (OC), short-circuit (SC), and cross-fault conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Compliance\u003c\/strong\u003e: Certified up to SIL3 according to IEC 61508 \/ IEC 61511 functional safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Form Factor\u003c\/strong\u003e: Features a signature blue structural extraction handle block for secure subrack alignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e: Supports active online hot-swapping inside a redundant chassis environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Mass (Net Component)\u003c\/strong\u003e: Approximately 0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Gross Shipping Mass\u003c\/strong\u003e: 3.0 kg (6.61 lbs) heavy-duty protective boxing layout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Ambient Temperature\u003c\/strong\u003e: -5°C to +70°C panel enclosure limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Shutdown (ESD) Valve Control\u003c\/strong\u003e: Manages the continuous 24V DC power loop fed to critical fuel isolation solenoid valves, executing immediate power-to-trip shutoffs when process boundaries breach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurner Management System (BMS) Interlocks\u003c\/strong\u003e: Regulates the main gas trip valves for industrial boiler systems, ensuring fuel drops completely out if flame scanners flag a hazard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Siren and Strobe Activation\u003c\/strong\u003e: Drives high-draw audible sirens and emergency warning lighting grids across gas storage yards during an uncontained chemical release.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire and Gas (F\u0026amp;G) Extinguishing Triggers\u003c\/strong\u003e: Sends high-availability digital output impulses to release fire suppression agents or deluge systems when logic solvers receive confirmed hazard alerts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45025527595123,"sku":"FC-SDO-O824","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-22_09-47-53.png?v=1779415769","url":"https:\/\/www.dcssupplier.com\/products\/honeywel-fc-sdo-o824-safety-manager-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}