{"product_id":"honeywell-10006-2-1-008804-digital-output-module","title":"Honeywell 10006\/2\/1-008804 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 10006\/2\/1-008804\u003c\/strong\u003e , also cataloged as the \u003cstrong\u003e10006\/2\/1\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for driving discrete field actuators and control loops within Honeywell process automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10006\/2\/1-008804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 10006 Series rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e6 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 550 mA per channel (Up to 13 W load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2500 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module executes switching logic for six discrete 24 VDC output channels, each supporting up to 550 mA current delivery for driving field loads up to 13 W, including solenoid valves and actuators. Built-in 2500 Vdc high-voltage isolation separates field circuits from internal backplane logic, preventing transient voltage surges and common-mode electrical noise from interfering with system processing. Integrated channel monitoring routines enforce fail-safe execution states in the event of system communication loss or supply voltage drops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What protection measures prevent high-voltage transients on field wiring from damaging internal backplane electronics?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates a galvanic isolation barrier rated at 2500 Vdc between the output channel terminals and the internal backplane bus, suppressing common-mode noise and electrical surges.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 10006\/2\/1-008804 module drive inductive loads directly without external suppression diodes?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports up to 550 mA (13 W) at 24 VDC. However, installing external flywheel diodes directly across inductive field loads such as solenoid coils is recommended to limit back-EMF voltage spikes during switching.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the rack backplane power source prior to inserting or removing the module from its slot.\u003c\/li\u003e\n\u003cli\u003eConfirm field actuator current draw does not exceed 550 mA (13 W) at 24 VDC per output point.\u003c\/li\u003e\n\u003cli\u003eRoute digital output wiring away from high-voltage AC lines, utilizing shielded cable assemblies grounded at a single cabinet earth point.\u003c\/li\u003e\n\u003cli\u003eVerify cabinet ambient environmental conditions remain within the operating limits of -20 deg C to 70 deg C to prevent thermal overload.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45443114664051,"sku":"10006\/2\/1-008804","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1000621_2_22f973d3-c094-47cf-ae03-34201ce2f9a9.jpg?v=1788493800","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-10006-2-1-008804-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}