{"product_id":"honeywell-10105-2-1-fail-safe-high-density-analog-input-module","title":"Honeywell 10105\/2\/1 Fail-Safe High-Density Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 10105\/2\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10105\/2\/1\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-density analog signal acquisition and safety loop execution within Fail-Safe Control (FSC) systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10105\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 35 mA, 24 VDC at 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 fail-safe analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4.1 V (converted from 0-20 mA via FTA-T-14 or 10105\/A\/1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (inaccuracy ± 1 LSB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Inaccuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eDesigned for SIL3 \/ AK1-6 safety instrumented applications, the module features high-impedance input architecture (\u0026gt; 1 MOhm) with crosstalk suppression exceeding 60 dB to maintain signal integrity across high-density loop configurations. Galvanic isolation and external voltage readback capabilities (0 to 4.1 V) enforce continuous diagnostic coverage and immediate fail-safe state execution in the event of field loop anomalies or backplane signal disruption.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are standard 0-20 mA or 4-20 mA field current signals conditioned for this module?\u003c\/p\u003e\n\u003cp\u003eA: Current-to-voltage conversion (0-20 mA to 0-4.1 V) must be executed using either the FTA-T-14 Field Termination Assembly or the 10105\/A\/1 conversion module mounted on the rear backplane programming connector (Px).\u003c\/p\u003e\n\u003cp\u003eQ: What safety classification does the module support in redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: The module is certified for safety class AK1-6 in single mode and achieves AK6 performance levels when deployed in dual redundant hardware setups.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module withstand accidental high-voltage wiring errors on the input channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each input channel is protected against sustained overvoltage conditions up to an absolute maximum input limit of ± 36 VDC without permanent board damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the 4 HP, 3U module into the specified slot of the 19-inch FSC subrack, ensuring correct alignment with backplane guide rails.\u003c\/li\u003e\n\u003cli\u003eEnsure the 10105\/A\/1 conversion module is firmly seated on the corresponding Px connector on the backplane if FTA-T-14 field termination assemblies are not utilized.\u003c\/li\u003e\n\u003cli\u003eKeep field analog signal cabling routed in twisted, shielded pairs, connecting the shield ground exclusively at the designated system earth point.\u003c\/li\u003e\n\u003cli\u003eCheck that external 24 VDC power supply ripple does not exceed safety limits before powering up the channel inputs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970850525299,"sku":"10105\/2\/1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/101012_Cocoai_6fd2a172-a92e-46c1-858d-7d1bd50ab493.jpg?v=1792139642","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-10105-2-1-fail-safe-high-density-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}