{"product_id":"honeywell-10310-2-1-digital-i-o-cards","title":"Honeywell 10310\/2\/1 Digital I\/O Cards","description":"\u003cp\u003eConfigured for discrete load switching and ground fault monitoring in FSC system platforms, the \u003cstrong\u003eHoneywell 10310\/2\/1\u003c\/strong\u003e (\u003cstrong\u003e10310\/2\/1\u003c\/strong\u003e Earth Leakage Detector \u0026amp; Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10310\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs (0.16 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FSC Rack Slot Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal \/ 115 VAC backplane loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eEarth Leakage Detection (ELD) and Digital Output Execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eOperating as a critical interface board, the unit incorporates channel-to-channel isolation barriers to restrict ground fault current propagation across the system backplane. Integrated Earth Leakage Detector (ELD) circuitry monitors insulation resistance between active field conductors and ground rails, triggering trip signals when leakage thresholds are breached. Backplane logic networks utilize isolated signal paths and low-drift current sensing stages, maintaining continuous diagnostic readback and loop state verification without thermal signal interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the output voltage and current handling capabilities of this module?\u003c\/p\u003e\n\u003cp\u003eA: The digital output channels support switching operations at 24 VDC or 115 VAC with a continuous load current rating up to 1 A per channel.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle ground fault detection on connected loops?\u003c\/p\u003e\n\u003cp\u003eA: The onboard Earth Leakage Detector (ELD) continuously checks field loops for current imbalance or low insulation resistance relative to frame earth, isolating faults before backplane power integrity is compromised.\u003c\/p\u003e\n\u003cp\u003eQ: Is live hot-swapping permitted for this output card?\u003c\/p\u003e\n\u003cp\u003eA: No, extracting or inserting the module while the subrack power bus is active can induce transients on switching outputs or trigger false ground fault trips. System power must be isolated prior to module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInsert the card into its assigned subrack slot, aligning top and bottom edge card guides to prevent pin deformation on the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSecure front-panel retaining screws to establish low-impedance mechanical chassis grounding to the rack enclosure.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring using shielded twisted pairs, maintaining separation between 24 VDC low-voltage logic cables and 115 VAC load lines.\u003c\/li\u003e\n\u003cli\u003eVerify that field ground drain wires connect directly to the main system earth bar to ensure accurate earth leakage detection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43635661209715,"sku":"10310\/2\/1","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/101063_Cocoai_1_74e5640c-038f-43eb-b6af-9e9e4e6866ca.jpg?v=1792139687","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-10310-2-1-digital-i-o-cards","provider":"DcsSupplier Limited","version":"1.0","type":"link"}