{"product_id":"honeywell-51196742-500-cordset","title":"Honeywell 51196742-500 Cordset","description":"\u003cp\u003eConfigured for high-reliability signal transmission in industrial control networks, the \u003cstrong\u003eHoneywell 51196742-500\u003c\/strong\u003e (\u003cstrong\u003e51196742-500\u003c\/strong\u003e Cordset) provides direct physical\/electrical execution of 15-pin to 15-pin data interfacing between Honeywell control modules and auxiliary peripheral devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51196742-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.41 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSystem specific length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e15-pin male to 15-pin male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The cordset maintains the shielding continuity required to interface with analog signal conditioning racks. It ensures that critical HART diagnostic data remains free from attenuation when routed through high-density DCS cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e This assembly serves as a physical transport medium for localized fieldbus segments. It is engineered to maintain low signal impedance and minimize propagation delay, which is mandatory for maintaining the deterministic scan cycles of connected control devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal shielding of the cordset is designed to decouple signal lines from external electromagnetic fields. This is mandatory to prevent crosstalk between adjacent control loops in multi-channel interface scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The connector contacts utilize high-conductivity materials that minimize localized thermal EMF. This is mandatory when interfacing with precision thermocouple or RTD input modules, ensuring that the DCS accurately interprets field-side temperature values without artificial drift.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 51196742-500 cordset compatible with custom wiring configurations for non-Honeywell peripherals?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal wiring map of this cordset is proprietary to Honeywell system specifications. Utilizing this cable for non-compliant hardware may result in incorrect pin assignment, potentially leading to electrical shorts or hardware damage to connected I\/O ports.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cordset be used in hazardous area (Ex) rated zones?\u003c\/p\u003e\n\u003cp\u003eA: This cable is not intrinsically safe by itself. Usage in hazardous zones is strictly regulated by system-wide installation requirements. Verify that the routing path and the connected I\/O modules meet the site-specific Intrinsic Safety (Ex i) barrier requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the 15-pin male connectors are fully seated and that the integrated retaining screws are tightened to maintain electrical continuity. Loose connections are a primary cause of intermittent data loss and increased resistance in control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The cable shield must be bonded to the cabinet’s instrument earth bus. A low-impedance ground connection is mandatory to ensure the shield effectively mitigates electromagnetic noise and protects sensitive control signals from transient surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Keep the cordset separated from high-voltage power conduits by at least 150 mm. This isolation is mandatory to prevent inductive coupling, which is critical for maintaining the high-speed data integrity required by DCS interface modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45189671059571,"sku":"51196742-500","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-07_10-10-36_57e56775-288c-4442-9c10-09464ac4e46a.png?v=1783503376","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-51196742-500-cordset","provider":"DcsSupplier Limited","version":"1.0","type":"link"}