{"product_id":"honeywell-51196814-200-differential-pressure-transmitter","title":"Honeywell 51196814-200 Differential Pressure Transmitter","description":"\u003cp\u003eConfigured for precise pressure differential monitoring in process control architectures, the \u003cstrong\u003eHoneywell 51196814-200\u003c\/strong\u003e (\u003cstrong\u003e51196814-200\u003c\/strong\u003e Differential Pressure Transmitter) provides direct physical\/electrical execution of gas-phase pressure sensing and signal conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51196814-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard transmitter form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Media\u003c\/td\u003e\n\u003ctd\u003eAir, non-conductive\/non-corrosive gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The transmitter interfaces with DCS controllers via standardized loop current, supporting the transmission of calibrated pressure variables and diagnostic status data required for industrial process optimization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The device architecture facilitates integration into intelligent instrumentation networks, enabling remote configuration and real-time monitoring of pressure trends within the control environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal signal conditioning circuitry provides galvanic decoupling from the power supply, preventing common-mode noise and ground potential shifts from affecting the sensitivity of the differential pressure measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The transmitter utilizes internal thermal management to maintain measurement stability within the operating temperature range, compensating for potential thermal drift in the sensing element.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the transmitter be used with corrosive or conductive media?\u003c\/p\u003e\n\u003cp\u003eA: No. The sensing element is rated exclusively for air, non-conductive, or non-corrosive gases. Exposure to corrosive or conductive media will compromise the internal pressure diaphragm and void the calibration.\u003c\/p\u003e\n\u003cp\u003eQ: How is the transmitter integrated with the Experion PKS control system?\u003c\/p\u003e\n\u003cp\u003eA: Integration is achieved through the 4-20 mA loop input modules within the Experion PKS or FSC backplane. Ensure the loop resistance is within the transmitter's specified operating range for optimal signal accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the polycarbonate chassis to a stable surface using the provided mounting points. Ensure the orientation minimizes vibration, as mechanical stress can introduce measurement bias.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the transmitter housing and cable shield to the cabinet’s protective earth (PE) bus. This connection is necessary for electromagnetic immunity and to provide a consistent reference for the signal output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate the connection using the pluggable terminal strip. Maintain a minimum 150 mm separation from high-power AC or variable frequency drive cables to eliminate induced signal ripple and ensure long-term stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45223181647987,"sku":"51196814-200","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-13_11-27-14.png?v=1783914899","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-51196814-200-differential-pressure-transmitter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}