{"product_id":"honeywell-51199588-100-analog-input-module","title":"Honeywell 51199588-100 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51199588-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51199588\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for signal acquisition within Honeywell TDC 3000 systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51199588-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 independent inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 VDC, plus\/minus 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplus\/minus 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack-mounted TDC 3000 I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard chassis-module unit weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCustom TDC 3000 chassis-slot profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration \u0026amp; Signal Safeguards\u003c\/h3\u003e\n\u003cp\u003eThe 51199588-100 is engineered to isolate and process critical analog measurements prior to system logic execution:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Shielding:\u003c\/strong\u003e The module’s input filter circuitry prevents high-frequency digital HART handshake frequencies from degrading the underlying analog current measurements, keeping loop conversion stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Protocols:\u003c\/strong\u003e Each of the 4 channels features hardware-level galvanic isolation barriers. This design prevents field-side ground differentials or cross-channel common-mode voltages from propagating to the TDC 3000 backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Cold Junction Compensation Alignment:\u003c\/strong\u003e When paired with external thermocouple termination assemblies, the internal processing engine references stable ambient measurement points to sustain high-accuracy temperature calibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be hot-swapped while the TDC 3000 I\/O rack is fully energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. To prevent potential backplane bus errors or signal dropouts on adjacent active cards, the I\/O slot power must be isolated or the rack powered down before extracting or inserting the 51199588-100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle a field wire break on a 4-20 mA loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The card detects undercurrent faults below 3.6 mA as a downscale open-circuit condition, immediately flagging a channel diagnostic fault bit to the controller for safety shutdown execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion Alignment:\u003c\/strong\u003e Align the module card-edge connector with the chassis guides. Slide the card smoothly into the slot and actuate the mechanical locking handles to seat the multi-pin connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shield Grounding:\u003c\/strong\u003e Ground incoming field instrument shields at the marshalling panel's single-point earth bar. Do not terminate cable shields at both the field device and the I\/O rack to avoid ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Voltage Routing Rules:\u003c\/strong\u003e Keep all 4-20 mA and VDC input wires in separate wire ducts isolated from AC power distribution lines to maintain measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Vent Clearances:\u003c\/strong\u003e Ensure the top and bottom ventilation slots of the TDC 3000 I\/O chassis are kept clear of obstructions to facilitate convective cooling across the module under peak thermal loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45238621077619,"sku":"51199588-100","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-15_13-51-39_c1687706-3753-4f56-8065-e458adb0ec63.png?v=1784099507","url":"https:\/\/www.dcssupplier.com\/products\/honeywell-51199588-100-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}